| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
HCS08 bảng dữ liệu(PDF) 37 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
HCS08 bảng dữ liệu(HTML) 37 Page - NXP Semiconductors |
|
37 / 374 page ![]() Chapter 3 Modes of Operation MC9S08JM60 Series Data Sheet, Rev. 5 Freescale Semiconductor 37 3.6 Stop Modes One of two stop modes is entered upon execution of a STOP instruction when STOPE in SOPT1 is set. In any stop mode, the bus and CPU clocks are halted. The MCG module can be configured to leave the reference clocks running. See Chapter 12, “Multi-Purpose Clock Generator (S08MCGV1),” for more information. Table 3-1 shows all of the control bits that affect stop mode selection and the mode selected under various conditions. The selected mode is entered following the execution of a STOP instruction. 3.6.1 Stop3 Mode Stop3 mode is entered by executing a STOP instruction under the conditions as shown in Table 3-1. The states of all of the internal registers and logic, RAM contents, and I/O pin states are maintained. Stop3 can be exited by asserting RESET, or by an interrupt from one of the following sources: the real-time clock (RTC) interrupt, the USB resume interrupt, LVD, ADC, IRQ, KBI, SCI, or the ACMP. If stop3 is exited by means of the RESET pin, then the MCU is reset and operation will resume after taking the reset vector. Exit by means of one of the internal interrupt sources results in the MCU taking the appropriate interrupt vector. 3.6.1.1 LVD Enabled in Stop Mode The LVD system is capable of generating either an interrupt or a reset when the supply voltage drops below the LVD voltage. If the LVD is enabled in stop (LVDE and LVDSE bits in SPMSC1 both set) at the time the CPU executes a STOP instruction, then the voltage regulator remains active during stop mode. If the user attempts to enter stop2 with the LVD enabled for stop, the MCU will enter stop3 instead. For the ADC to operate, the LVD must be left enabled when entering stop3. For the ACMP to operate when ACGBS in ACMPSC is set, the LVD must be left enabled when entering stop3. For the XOSC to operate with an external reference when RANGE in MCGC2 is set, the LVD must be left enabled when entering stop3. Table 3-1. Stop Mode Selection STOPE ENBDM 1 1 ENBDM is located in the BDCSCR which is only accessible through BDC commands, see Section 18.4.1.1, “BDC Status and Control Register (BDCSCR).” LVDE LVDSE PPDC Stop Mode 0 x x x Stop modes disabled; illegal opcode reset if STOP instruction executed 1 1 x x Stop3 with BDM enabled 2 2 When in stop3 mode with BDM enabled, The S IDD will be near RIDD levels because internal clocks are enabled. 1 0 Both bits must be 1 x Stop3 with voltage regulator active 1 0 Either bit a 0 0 Stop3 1 0 Either bit a 0 1 Stop2 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |