| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
P9S12XEP100J1VVLR bảng dữ liệu(PDF) 993 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
P9S12XEP100J1VVLR bảng dữ liệu(HTML) 993 Page - Freescale Semiconductor, Inc |
|
993 / 1324 page ![]() Chapter 26 384 KByte Flash Module (S12XFTM384K2V1) MC9S12XE-Family Reference Manual , Rev. 1.21 Freescale Semiconductor 993 26.4.2.7 Program Once Command The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the nonvolatile information register located in P-Flash block 0. The Program Once reserved field can be read using the Read Once command as described in Section 26.4.2.4. The Program Once command must only be issued once since the nonvolatile information register in P-Flash block 0 cannot be erased. The Program Once command must not be executed from the Flash block containing the Program Once reserved field to avoid code runaway. Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed. The reserved nonvolatile information register accessed by the Program Once command cannot be erased and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index Table 26-44. Program P-Flash Command Error Handling Register Error Bit Error Condition FSTAT ACCERR Set if CCOBIX[2:0] != 101 at command launch Set if command not available in current mode (see Table 26-30) Set if an invalid global address [22:0] is supplied(1) 1. As defined by the memory map for FTM512K3. Set if a misaligned phrase address is supplied (global address [2:0] != 000) Set if a Load Data Field command sequence is currently active and the selected block has previously been selected in the same command sequence Set if a Load Data Field command sequence is currently active and global address [17:0] does not match that previously supplied in the same command sequence FPVIOL Set if the global address [22:0] points to a protected area MGSTAT1 Set if any errors have been encountered during the verify operation MGSTAT0 Set if any non-correctable errors have been encountered during the verify operation FERSTAT EPVIOLIF None Table 26-45. Program Once Command FCCOB Requirements CCOBIX[2:0] FCCOB Parameters 000 0x07 Not Required 001 Program Once phrase index (0x0000 - 0x0007) 010 Program Once word 0 value 011 Program Once word 1 value 100 Program Once word 2 value 101 Program Once word 3 value |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |