| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
P9S12XEP100J1VVLR bảng dữ liệu(PDF) 930 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
P9S12XEP100J1VVLR bảng dữ liệu(HTML) 930 Page - Freescale Semiconductor, Inc |
|
930 / 1324 page ![]() Chapter 25 256 KByte Flash Module (S12XFTM256K2V1) MC9S12XE-Family Reference Manual , Rev. 1.21 930 Freescale Semiconductor CAUTION A P-Flash phrase must be in the erased state before being programmed. Cumulative programming of bits within a Flash phrase is not allowed. Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the data words to the supplied global address and will then proceed to verify the data words read back as expected. The CCIF flag will set after the Program P-Flash operation has completed. 25.4.2.7 Program Once Command The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the nonvolatile information register located in P-Flash block 0. The Program Once reserved field can be read using the Read Once command as described in Section 25.4.2.4. The Program Once command must only be issued once since the nonvolatile information register in P-Flash block 0 cannot be erased. The Program Table 25-43. Program P-Flash Command FCCOB Requirements CCOBIX[2:0] FCCOB Parameters 000 0x06 Global address [22:16] to identify P-Flash block 001 Global address [15:0] of phrase location to be programmed(1) 1. Global address [2:0] must be 000 010 Word 0 program value 011 Word 1 program value 100 Word 2 program value 101 Word 3 program value Table 25-44. Program P-Flash Command Error Handling Register Error Bit Error Condition FSTAT ACCERR Set if CCOBIX[2:0] != 101 at command launch Set if command not available in current mode (see Table 25-30) Set if an invalid global address [22:0] is supplied Set if a misaligned phrase address is supplied (global address [2:0] != 000) Set if a Load Data Field command sequence is currently active and the selected block has previously been selected in the same command sequence Set if a Load Data Field command sequence is currently active and global address [17:0] does not match that previously supplied in the same command sequence FPVIOL Set if the global address [22:0] points to a protected area MGSTAT1 Set if any errors have been encountered during the verify operation MGSTAT0 Set if any non-correctable errors have been encountered during the verify operation FERSTAT EPVIOLIF None |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |