| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
EB632 bảng dữ liệu(PDF) 61 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
EB632 bảng dữ liệu(HTML) 61 Page - Freescale Semiconductor, Inc |
|
61 / 112 page ![]() Errata Functional Differences Between MSC8101 (Mask 2K42A) and MSC8103 (Mask 2K87M), Rev. 2 Freescale Semiconductor 61 GEN2 Unexpected Outputs During Boundary Scan Date Added: 10/18/2002 Description: D[32:60] outputs may behave indeterminately during boundary scan. Workaround: Reset the device by asserting PORESET while HPE/EE1=0. Alternatively, assert PORESET throughout boundary scan. Fix Plan: RevA 0K40A 1K42A 2K42A SC1 PC Cannot Be Updated in Debug Mode Entered From Asynchronous Interrupt Date Added: 10/5/2000 Description: When a DEBUG instruction is executed in a static or dynamic delay slot created by an asynchronous interrupt, the core enters Debug mode, but the PC cannot be updated. Workaround: In the dynamic case, the debugger can use a status bit in the ESR, which indicates whether the core entered a debug in a delay slot. Software workarounds are available for all the static cases. A detailed description was sent by StarCore and can be resent upon request. 0K40A 1K42A 2K42A SC3 Erroneous Trace Buffer Value Date Added: 10/5/2000 Description: An erroneous 62-bit value may be written to the trace buffer when the EOnCE is programmed to write both event counters (ECNT_VAL and ECNT_EXT). Workaround: None. 0K40A 1K42A 2K42A CPM2 CAM Access Not Atomic Date Added: 5/30/2000: Description: The bus atomicity mechanism for CAM access may not function correctly when the CPM’s DMA accesses the CAM. This only affects systems in which multiple CPMs will ac- cess the CAM. Workaround: None System Number: 1410 0K40A 1K42A 2K42A CPM4 No CTS Lost Indication with HDLC Date Added: 5/30/2000 Description: When CTS is deasserted at the end of hdlc frame, (last flag or one bit before) trans- mission will be aborted. However there is no CTS-LOST indication. There is only abort indica- tion. Workaround: None System Number: 1670 0K40A 1K42A 2K42A CPM5 Data Corruption on SDMA Flyby Date Added: 5/30/2000 Description: The data of a SDMA write, which follows a SDMA flyby read in the local bus may be corrupted. Workaround: None System Number: 1720 0K40A 1K42A 2K42A Table 48. Errata Resolved in Mask Set 2K87M (Continued) Errata Number Errata Description Applies to Mask |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |