57 / 112 page ![]() Errata Functional Differences Between MSC8101 (Mask 2K42A) and MSC8103 (Mask 2K87M), Rev. 2 Freescale Semiconductor 57 SIU8 Parity Checking Error Date Added: 6/13/2000: Description: During a read from a device with port size less than 64 bits, from an address not aligned to 64 bits, the parity bits for parity check are not taken from the correct locations. For ex- ample, for a read of 4 bytes from a 32-bit port size from address 4, the parity is checked against DP[4–7] while it should be checked against DP[0–3]. The bug exists for both normal and rmw parity, and for both System and Local buses. Workaround: None System Number: 5839 0K40A 1K42A 2K42A SIU9 Bus Monitor Asserts Spurious TEA After Address Retry. Date Added: 1/28/2001 Description: The bus monitor will not recognize the competition of an Address Retry transaction and will assert TEA if there is no bus activity for a time equal to the expiration time. Workaround: Disable the bus monitor in systems where Address Retry cycles are used (e.g. sys- tems which include PowerSpan). 0K40A 1K42A 2K42A SIU10 Strict Enforcement of Requirement to Assert DBG and TS in Same Cycle When Core En- abled Date Added: 1/28/2001 Description: This is a compatibility note. An external arbiter must assert DBG in the same clock in which TS is asserted (there may be a one clock delay if the PPC_ACR[DBGD] bit is set, how- ever, after reset this bit is not set by default). Some external arbiters, including the one implement- ed in PowerSpan, violate this requirement. As a result, the system hangs following the first bus access after reset. Workaround: Use only a compliant external arbiter or the internal MSC8101 arbiter. 0K40A 1K42A 2K42A QSIU3 TEA May Hang 60x-Compatible Bus Date Added: 5/30/2000 Description: TEA may hang the 60x-compatible bus if it is asserted between specific address and data phases during a split transaction. Workaround: Enable Bus Monitor. Fix Plan: Rev. A 0K40A 1K42A 2K42A QSIU5 Incorrect Data on 60x-Compatible Bus Date Added: 6/13/2000 Description: The following sequence on the 60x-compatible bus can result in incorrect data: 1. Read transaction with DACK before AACK. 2. Failed atomic write transaction. 3. Write transaction. Workaround: None. System Number: 5823 0K40A 1K42A 2K42A Table 48. Errata Resolved in Mask Set 2K87M (Continued) Errata Number Errata Description Applies to Mask |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |