| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
UTG11823P bảng dữ liệu(PDF) 77 Page - FCI connector |
|
|
|||||||||||||||||||||||||||||
UTG11823P bảng dữ liệu(HTML) 77 Page - FCI connector |
|
77 / 101 page ![]() Contacts 79 From simple calculations, one can see that the closer the bundle approaches the single wire condition, the higher the allowable current per conductor becomes, to even such an extent, that it exceeds the recommended continuous current value. In that case, the recommended continuous value should have preference. In order to make this clear, we will give some typical examples. • Example 1 Cable bundle, 48 conductors AWG20 (0.5mm2) used with circular TrimTrio connector with insert arrangement 24-48 and machined size 16 contacts RM/RC20. - Total operating current capacity of bundle 48 x 7.5 A ( table I) = 360 A - Total allowable capacity for bundles of more than 15 wires is 20% = 72 A - When all conductors are energized equally, this gives: 72 : 48 = 1.5 A per conductor When for instance 5 conductors are energized to the recommended continuous current of 5 A (see table 1) resulting in 25 A consumption, the other conductors may not take more than 72 - 25 = 47 A all together, or 1 A per conductor. Any other combination can of course also be taken as long as the total capacity of 72 A is not exceeded and the recommended continuous current is respected. Remark Please note that contacts used are of the size 16 type with maximum operating current of 13 A (table 2). The maximum operating current of the bundle is however restricted to 7.5 A per conductor due to the wire size of AWG20 (see table 1). • Example 2 Cable bundle, 14 conductors AWG22 (0.32 mm2) used with rectangular Trim Trio connector with insert arrangement for 14 contacts, and machined size 16 contacts RM / RC20. - Total operating current capacity of bundle 14 x 5 (table I) = 70 A - Total allowable for wire bundle of 15 wires less 1 is 20% + 6% = 26% gives 18.2 A. - All conductors energized equally, gives: 18.2 : 14 = 1.3 A per conductor This value is within the recommended rating of 3 A so that it can be applied. See also remark under example 1. • Example 3 Cable bundle, 4 conductors AWG16 (1.3mm2) used with circular Trim Trio connector with insert arrangement 10-4 and stamped 2 piece contacts SM /SC. - Total operating current capacity of bundle 4 x 13 A (table I) = 52 A - Total allowable for wire bundle of 15 wires less 11 is 20% + 66% = 86% gives 44.7 A. - All conductors energized equally, gives: 44.7 : 4 = 11.2 A per conductor Since the recommended continuous current is 10 A, the conductor should not carry more than 10 A individiually. As said before, the recommended ratings are valid for most common wiring systems and under normal working conditions. For extreme conditions, the given values should be lowered. The percentage of current reduction should be investigated from case to case. A rule-of thumb which can be used for such cases is: 4 Amp. per mm2 wire section It gives us for common used wire sizes the values listed in table 3. 26 0.13 0.5 24 0.20 0.8 22 0.32 1.3 20 0.52 2.0 18 0.82 3.3 16 1.30 5.2 14 2.10 8.4 AWG wire size recommended mm2 continuous current Amp. Table 3 - Recommended continuous current for extreme working conditions |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |