Back Button TMP411D Datasheet HTML 33Page - Texas Instruments TMP411D Datasheet HTML 34Page - Texas Instruments TMP411D Datasheet HTML 35Page - Texas Instruments TMP411D Datasheet HTML 36Page - Texas Instruments TMP411D Datasheet HTML 37Page - Texas Instruments TMP411D Datasheet HTML 38Page - Texas Instruments TMP411D Datasheet HTML 39Page - Texas Instruments TMP411D Datasheet HTML 40Page - Texas Instruments TMP411D Datasheet HTML 41Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 60 page
background image
Table 8-6. N-Factor Range (continued)
NADJUST
N
BINARY
HEX
DECIMAL
0000 0100
04
4
1.021622
0000 0010
02
2
1.014765
0000 0001
01
1
1.011371
0000 0000
00
0
1.008
1111 1111
FF
−1
1.004651
1111 1110
FE
−2
1.001325
1111 1100
FC
−4
0.994737
1111 1010
FA
−6
0.988235
1111 1000
F8
−8
0.981818
1111 0110
F6
−10
0.975484
1000 0000
80
−128
0.706542
8.10 Minimum and Maximum Registers
The TMP411-Q1 and TMP411D-Q1 stores the minimum and maximum temperature measured since power
on, chip reset, or minimum and maximum register reset for both the local and remote channels. The Local
Temperature Minimum Register is read with the high byte from pointer address 30h, and the low byte is read
from pointer address 31h. The Local Temperature Minimum Register is read with a two-byte read command from
pointer address 30h. The Local Temperature Minimum Register resets at power-on by executing the chip-reset
command, or by writing any value to any of the pointer addresses 30h through 37h. The reset value for these
registers is FFh/F0h.
The Local Temperature Maximum Register is read with the high byte from pointer address 32h and the low byte
from pointer address 33h. The Local Temperature Maximum Register is read with a two-byte read command
from pointer address 32h. The Local Temperature Maximum Register resets at power-on by executing the chip
reset command, or by writing any value to any of the pointer addresses 30h through 37h. The reset value for
these registers is 00h/00h.
The Remote Temperature Minimum Register is read with the high byte from pointer address 34h and the
low byte from pointer address 35h. The Remote Temperature Minimum Register is read with a two-byte
read command from pointer address 34h. The Remote Temperature Minimum Register resets at power-on by
executing the chip reset command, or by writing any value to any of the pointer addresses 30h through 37h. The
reset value for these registers is FFh/F0h.
The Remote Temperature Maximum Register is read with the high byte from pointer address 36h and the
low byte from pointer address 37h. The Remote Temperature Maximum Register is read with a two-byte
read command from pointer address 36h. The Remote Temperature Maximum Register resets at power-on
by executing the chip reset command, or by writing any value to any of the pointer addresses 30h through 37h.
The reset value for these registers is 00h/00h.
8.11 Consecutive Alert Register
The value in the Consecutive Alert Register (address 22h) determines how many consecutive out-of-limit
measurements must occur on a measurement channel before the ALERT signal is activated. The value in
this register does not affect bits in the Status Register. Values of one, two, three, or four consecutive conversions
can be selected; one conversion is the default. This function allows additional filtering for the ALERT pin. The
consecutive alert bits are shown in Table 8-7.
Table 8-7. Consecutive Alert Register
CONSECUTIVE ALERT REGISTER (READ = 22h, WRITE = 22h, POR = 01h)
C2
C1
C0
NUMBER OF CONSECUTIVE OUT OF LIMIT MEASUREMENTS
0
0
0
1
www.ti.com
TMP411-Q1, TMP411D-Q1
SBOS527G – DECEMBER 2010 – REVISED SEPTEMBER 2025
Copyright © 2025 Texas Instruments Incorporated
Submit Document Feedback
37
Product Folder Links: TMP411-Q1 TMP411D-Q1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com