20 / 60 page ![]() 7.2 Functional Block Diagram Device ID Register Manufacturer ID Registor THERM Hysteresis Register Consecutive Alert Configuration Register T T R L Status Register Conversion Rate Register N-Factor Correction One-Shot Register D+ 1 5 7 8 2 3 Bus Interface Pointer Register Resolution Register Configuration Register Local Temp Low Limit Local THERM Limit Local Temp High Limit Remote Temp Low Limit Remote THERM Limit Remote Temp High Limit Remote Temperature Register Local Temperature Register Temperature Comparators Interrupt Configuration SCL GND THERM 4 6 ALERT/THERM2 V+ V+ SDA D− TMP411-Q1 Remote Temperature Min/Max Register Local Temperature Min/Max Register Figure 7-2. Functional Block Diagram 7.3 Feature Description 7.3.1 Series Resistance Cancellation Figure 7-1 shows series resistance in an application circuit that results from printed circuit board (PCB) trace resistance and remote line length. The TMP411-Q1 and TMP411D-Q1 devices automatically cancel the resistance, which prevents a temperature offset. The TMP411-Q1 and TMP411D-Q1 devices cancel up to 3kΩ of series line resistance, which eliminates the need for additional characterization and temperature offset correction. See Figure 6-8 (Figure 6-9 for a new chip), Figure 6-10 (Figure 6-11 for a new chip), Figure 6-26 and Figure 6-27 for details on the effect of series resistance and power-supply voltage on sensed remote temperature error. 7.3.2 Differential Input Capacitance The TMP411-Q1 and TMP411D-Q1 devices tolerate differential input capacitance of up to 1000pF with minimal change in temperature error. The effect of capacitance on the sensed remote temperature error is shown in Figure 6-12 (Figure 6-13 for new chip) and Figure 6-28. 7.3.3 Temperature Measurement Data Temperature measurement data is taken over a default range of 0°C to 127°C for both local and remote locations. Measurements from –55°C to 150°C can be made both locally and remotely by reconfiguring the TMP411-Q1 and TMP411D-Q1 devices for the extended temperature range. To change the TMP411-Q1 and TMP411D-Q1 configuration from the standard to the extended temperature range, switch bit 2 (RANGE) of the Configuration Register from low to high. Temperature data resulting from conversions within the default measurement range are represented in binary form, as listed in the standard binary column of Table 7-1. Note that any temperature below 0°C results in a data value of zero (00h). Likewise, temperatures above 127°C result in a value of 127 (7Fh). The device can be set to measure over an extended temperature range by changing bit 2 of the Configuration Register from low to high. The change in measurement range and data format from standard binary to extended binary occurs at the next temperature conversion. For data captured in the extended temperature range configuration, an TMP411-Q1, TMP411D-Q1 SBOS527G – DECEMBER 2010 – REVISED SEPTEMBER 2025 www.ti.com 20 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: TMP411-Q1 TMP411D-Q1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |