100 / 140 page ![]() TLE9461ES Lite CAN SBC Family Serial Peripheral Interface Datasheet 100 Rev.1.1 2019-09-27 Certain SPI control bits used to configure device functionality can be locked to avoid unintentional bit modification. The respective bit type is ‘rwl’. There are two levels of configuration locks: • CFG_LOCK_0 in the HW_CTRL_1 is the level 0 lock mechanism: The bits CP_EN and GPIO can be locked. In case the configuration must be changed then CFG_LOCK_0 must be cleared first • CFG_LOCK_1 in the HW_CTRL_2 is the level 1 lock mechanism: All other lockable bits with the type ‘rwl’ are locked and can only be modified at the next device power up No status information can be lost, even if a bit changes right after the first 7 SPI clock cycles before the SPI frame ends. In this case the status information field is updated with the next SPI command. However, the flag is already set in the relevant status register. The SBC status information from the SPI status registers is transmitted in a compressed format with each SPI response on SDO in the so-called Status Information Field register (see also Figure 40). The purpose of this register is to quickly signal changes in the SPI status registers to the microcontroller. This means that the microcontroller only needs to read registers which have changed. Each bit in the Status Information Field represents a SPI status register (see Table 26). As soon as one bit is set in one of the status registers, the corresponding bit in the Status Information Field register is set. Only the most important registers are represented in the Status Information Field, e.g. the register WK_LVL_STAT is not included. For example if bit 0 in the Status Information Field is set to ‘1’, one or more bits of the register 100 0001 (SUP_STAT_0) are set to 1. Then this register needs to be read with a second SPI command. The bit in the Status Information Field is set to 0 when all bits in the register 100 0001 have been reset to ‘0’. Table 26 Status Information Field Bit in Status Information Field Corresponding Address Bit Status Register Description 0 100 0001 SUP_STAT_0 - Supply Status: POR, VCC2 fail, VCC1 fail 1 100 0010 THERM_STAT - Thermal Protection Status 2 100 0011 DEV_STAT- Device Status: Mode before wake-up- up/failure, WD Fail, SPI Fail, Failure 3 100 0100 BUS_STAT - Bus Failure Status: CAN; 4 100 0110 100 0111 WK_STAT_0, WK_STAT_1 - Wake Source Status; Status bit is a combinational OR of both registers 5 100 0000 SUP_STAT_1: VS_UV, VCC1_WARN/OV 6 101 0100 GPIO_OC_STAT: GPIO over current 7 101 0101 GPIO_OL_STAT: GPIO open load |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |