| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TLC320AD50C/I bảng dữ liệu(PDF) 37 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLC320AD50C/I bảng dữ liệu(HTML) 37 Page - Texas Instruments |
|
37 / 54 page ![]() 4–4 4.3.7 DAC Dynamic Performance 4.3.7.1 DAC Signal-to-Noise When Load is 600 Ω (see Note 7 and Figure 5-13) PARAMETER TEST CONDITIONS TLC320AD50C/52C TLC320AD50I UNIT PARAMETER TEST CONDITIONS MIN TYP MAX MIN TYP MAX UNIT VI = 0 dB 85 89 83 87 Signal to noise ratio (SNR) VI = – 9 dB 76 80 74 78 dB Signal-to-noise ratio (SNR) VI = – 40 dB 45 49 43 47 dB VI = – 65 dB 20 24 18 22 NOTE 7: The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at output of application schematic low-pass filter. The test is conducted in 16-bit mode. 4.3.7.2 DAC Signal-to-Noise When Load is 10 k Ω (see Note 7) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VI = 0 dB 89 Signal to noise ratio (SNR) VI = – 9 dB 80 dB Signal-to-noise ratio (SNR) VI = – 40 dB 50 dB VI = – 65 dB 25 NOTE 7: The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at output of application schematic low-pass filter. The test is conducted in 16-bit mode. 4.3.7.3 DAC Signal-to- Distortion When Load is 600 Ω (see Note 7, Figure 5-14) PARAMETER TEST CONDITIONS TLC320AD50C/52C TLC320AD50I UNIT PARAMETER TEST CONDITIONS MIN TYP MAX MIN TYP MAX UNIT VI = – 3 dB 76 80 74 78 Signal to total harmonic distortion (THD) VI = – 9 dB 84 90 82 88 dB Signal-to-total harmonic distortion (THD) VI = – 40 dB 64 72 62 70 dB VI = – 65 dB 42 48 40 46 NOTE 7: The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at output of application schematic low-pass filter. The test is conducted in 16-bit mode. 4.3.7.4 DAC Signal-to- Distortion When Load is 10 k Ω (see Note 7) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VI = – 3 dB 82 Signal to total harmonic distortion (THD) VI = – 9 dB 91 dB Signal-to-total harmonic distortion (THD) VI = – 40 dB 77 dB VI = – 65 dB 49 NOTE 7: The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at output of application schematic low-pass filter. The test is conducted in 16-bit mode. 4.3.7.5 DAC Signal-to-Distortion+Noise When Load is 600 Ω (see Note 7, Figure 5-15) PARAMETER TEST CONDITIONS TLC320AD50C/52C TLC320AD50I UNIT PARAMETER TEST CONDITIONS MIN TYP MAX MIN TYP MAX UNIT VI = – 3 dB 75 79 72 76 Signal to total harmonic distortion + noise (THD + N) VI = – 9 dB 75 79 72 76 dB Signal-to-total harmonic distortion + noise (THD + N) VI = – 40 dB 45 49 42 46 dB VI = – 65 dB 20 24 17 21 NOTE 7: The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at output of application schematic low-pass filter. The test is conducted in 16-bit mode. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |