142 / 144 page ![]() 142 Am79C940 Status: No current plan to fix this item. 3) Flashing LED for Link Status: Description: When TMAU receiver is receiving negative polarity link pulse, and the automatic polarity correc- tion algorithm (DAPC bit in PHY Configuration Control Register) is disabled, link test state machine will loop between ’link fail’ and ’link pass’ state causing the Link Status LED to flash. Implication: There is no impact to system performance. However, the Link Status LED flashing may cause an erroneous interpretation by the user. Workaround: There is no workaround. Status: No current plan to fix this item. 4) Incorrect Runt Packet Count in Low Latency Receive Mode: Description: In Low Latency Receive mode, the MACE Runt Packet count is incremented when the receive packet is less than 12 bytes. The correct runt packet count should always be incremented when the receive packet is less than 64 bytes. Implication: There is no impact on system performance if the runt packet count is not being utilized by the system. Workaround: This condition is being validated at this time. Therefore, a workaround for this is to be deter- mined. 5) Device Failure at 1.25 MHz System Clock: Description: MACE device does not function reliability at system clock speed of less than 5MHz due to ar- chitecture constraints. Implication: There is no performance impact since the serial clock is still running at the IEEE specified 10MHz. Workarounds: 1. Avoid operating the MACE device at speeds of less than 5MHz. 2. Send one packet at a time. Essentially, write one packet to the transmit FIFO, let the Mace device transmit that packet, wait for the transmit complete interrupt, before writing another packet to the transmit FIFO. Status: No current plan to fix this item. 6) False BABL errors generated: Description: The MACE device will intermittenly give BABL error indications when the network traffic has frames equal to or greater than 1518 bytes. Implication: False BABL errors on the receiving station can be passed up to the upper layer software if MACE device is just coming out of deferral and the multi-purpose counter used to count the number of bytes recevied reaches 1518 at the same time. If the network is heavily loaded with full-size frames, then the probability of a false BABL error is high. Workaround: There are two possible workarounds. 1. If the user has no intention to transmit frames larger than 1518 bytes, then the BABL bit may be masked to ignore babble errors. In this case the false babble error will not cause an interrupt, nor will it be passed to the higher level software. 2. Check to see if the device is transmitting in ISR (Interrupt Service Routine), which is induced by the BABL error. The BCRs which control the LED settings can be programmed to indicate a transmit ac- tivity, assuming the interrupt latency is not longer than one mininum IFG (inter-frame gap) time. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |