| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
T25S16AFEPR bảng dữ liệu(PDF) 14 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
|
|||||||||||||||||||||||||||||
T25S16AFEPR bảng dữ liệu(HTML) 14 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
14 / 74 page ![]() 14 5.2.3 SFDP Header Field Definitions Table 5.3 SFDP Header SFDP Byte Address SFDP Dword Name Data Description 00h SFDP Header 1st DWORD 53h This is the entry point for Read SFDP (5Ah) command i.e. location zero within SFDP space ASCII “S” 01h 46h ASCII “F” 02h 44h ASCII “D” 03h 50h ASCII “P” 04h SFDP Header 2nd DWORD 06h SFDP Minor Revision (06h = JEDEC JESD216 Revision B) – This revision is backward compatible with all prior minor revisions. Minor revisions are changes that define previously reserved fields, add fields to the end, or that clarify definitions of existing fields. Increments of the minor revision value indicate that previously reserved parameter fields may have been assigned a new definition or entire Dwords may have been added to the parameter table. However, the definition of previously existing fields is unchanged and therefore remains backward compatible with earlier SFDP parameter table revisions. Software can safely ignore increments of the minor revision number, as long as only those parameters the software was designed to support are used i.e. Previously reserved fields and additional Dwords must be masked or ignored. Do not do a simple compare on the minor revision number, looking only for a match with the revision number that the software is designed to handle. There is no problem with using a higher number minor revision. 05h 01h SFDP Major Revision – This is the original major revision. This major revision is compatible with all SFDP reading and parsing software. 06h 00h Number of Parameter Headers (zero based, 00h = 1 parameters 07h FFh Unused 08h Parameter Header 0 1st DWORD 00h Parameter ID LSB (00h = JEDEC SFDP Basic SPI Flash Parameter) 09h 06h Parameter Minor Revision (00h = JESD216) –This older revision parameter header is provided for any legacy SFDP reading and parsing software that requires seeing a minor revision 6 parameter header. SFDP software designed to handle later minor revisions should continue reading parameter headers looking for a higher numbered minor revision that contains additional parameters for that software revision. 0Ah 01h Parameter Major Revision (01h = The original major revision - all SFDP software is compatible with this major revision. 0Bh 10h Parameter Table Length (in double words = Dwords = 4-byte units) 10h = 16 Dwords 0Ch Parameter Header 0 2nd DWORD 30h Parameter Table Pointer Byte 0 (Dword = 4-byte aligned) JEDEC Basic SPI Flash parameter byte offset = 30h 0Dh 00h Parameter Table Pointer Byte 1 0Eh 00h Parameter Table Pointer Byte 2 0Fh FFh Parameter ID MSB (FFh = JEDEC defined legacy Parameter ID) HM25Q128A |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |