| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
26HS01GTAM03 bảng dữ liệu(PDF) 81 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
26HS01GTAM03 bảng dữ liệu(HTML) 81 Page - Infineon Technologies AG |
|
81 / 166 page ![]() Datasheet 81 of 166 002-12337 Rev. *Y 2022-01-18 256Mb/512Mb/1Gb SEMPER™ Flash HYPERBUS™ interface, 1.8V/3.0V Features 4.13.2 Write buffer abort (Program abort / DICRC abort) If an error occurs during a Write to Buffer command, the device (EAC) remains busy. The Status Register shows ready with valid status bits. The device remains busy until the error status is detected by the host system status monitoring and the error status is cleared. During embedded algorithm error status the Status Register will show the following: • SR[7] = 1; Valid status displayed • SR[6] = X; May or may not be erase suspended during the WBA error status • SR[5] = 0; Erase successful • SR[4] = 1; Programming related error, else = 0 • SR[3] = 1; Write buffer abort • SR[2] = 0; No Program in suspension • SR[1] = 0; Sector not locked during operation • SR[0] = X; Treat as “don’t care” (masked) When the WBA error status is detected, it is necessary to clear the error status in order to return to normal operation, ready for a new read or command write. The error status can be cleared by writing: • Write Buffer Abort Reset command - Clears the Status Register and returns to normal operation • Status Register Clear command Commands that are accepted during embedded algorithm error status are: • Status Register Read - Reads the Status Register and returns to WBA busy state • Write Buffer Abort Reset command • Status Register Clear command During an embedded algorithm, read transactions not associated with a Status Register Read will toggle DS and return indeterminate data. 4.14 Error typer and reporting - Legacy (x1) SPI There are two types of errors reported by the embedded operation status methods. Depending on the error type, the status reported and procedure for clearing the error status is different. Table 60 and Table 61 provide the details for clearing the error status. Table 60 Program error (PRGERR) summary Error Flag Symbol Conditions Program Error PRGERR Bits cannot be programmed ‘1’ to ‘0’ Trying to program in a protected region If ASP0[2] or ASP0[1] is 0, any Nonvolatile Register write attempting to change the value of CFR1N[6:2]/CFR1V[6:2] After the Password Protection Mode is selected and ASP Password Register update transaction executed SafeBoot Failure Configuration Failure |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |