| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AS3517H-ECTP bảng dữ liệu(PDF) 85 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3517H-ECTP bảng dữ liệu(HTML) 85 Page - ams AG |
|
85 / 94 page ![]() AS3517 V17 Data Sheet, Confidential © 2003-2007, austriamicrosystems AG, 8141 Unterpremstaetten, Austria-Europe. All Rights Reserved. www.austriamicrosystems.com Table 88 Third Interrupt Register Name Base Default IRQ_ENRD_2 2-wire serial 00h Third Interrupt Register Offset: 25h Please be aware that writing to this register will enable/disable the corresponding interrupts, while with reading you get the actual interrupt status and will clear the register at the same time. It is not possible to read back the interrupt enable/disable settings. This register is reset at a DVDD-POR. Bit Bit Name Default Access Bit Description 0 W Battery over-temperature interrupt setting. 0: disable 1: enable interrupt if battery temperature exceeds 45°C The interrupt must not be enabled if the charger block and battery temperature supervision is disabled 7 BATTEMP_HIGH (level) x R Battery over-temperature interrupt reading 0: battery temperature below 45°C 1: battery temperature was too high and the charger was turned off. The charger will be turned on again, when the temperature gets below 42°C 0 W Battery end of charge interrupt setting 0: disable 1: enable The interrupt must not be enabled if the charger block is disabled 6 CHG_EOC (level) x R Battery end of charge interrupt reading 0: battery charging in progress 1: charging is complete, charging current is below 10% of nominal current, turn off charger To check end of charge again the charger has to be turned on. 5 CHG_STATUS x R 0: no charger input source connected 1: charger input source connected, also valid if charger is connected during wakeup 0 W Charger input status change interrupt setting 0: disable 1: enables an interrupt on a low to high or high to low change of CHGIN pin. 4 CHG_CHANGED (status change) x R Charger input status change interrupt reading 0: charger input status not changed 1: charger input status changed, check CHG_STATUS 3 USB_STATUS x R 0: no USB input connected 1: USB input connected, also valid if USB is connected during wakeup. The threshold can be set in the USB_UTIL register (1Ah) 0 W USB input status change interrupt setting 0: disable 1: enables an interrupt on a low to high or high to low change of VBUS pin. The threshold can be set in the USB_UTIL register (1Ah) 2 USB_CHANGED (status change) x R USB input status change interrupt reading 0: USB input status not changed 1: USB input status changed, check USB_STATUS Revision 1v3 84 - 93 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |