| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
BTS6480SF bảng dữ liệu(PDF) 46 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
BTS6480SF bảng dữ liệu(HTML) 46 Page - Infineon Technologies AG |
|
46 / 73 page ![]() Data Sheet 46 Rev. 1.0, 2010-04-12 SPOC - BTS6480SF Diagnosis For diagnosis feedback at different operation modes, please see following table. 9.1 Diagnosis Word at SPI The standard diagnosis at the SPI interface provides information about each channel. The error flags, an OR combination of the over temperature flags and the over load monitoring signals are provided in the SPI standard diagnosis bits ERRn. The over load monitoring signals are latched in the error flags and cleared each time the standard diagnosis is transmitted via SPI. In detail, they are cleared between the second and third raising edge of the SCLK signal. The over temperature flags, which cause an overheated channel to latch off, are latched directly at the gate control block. The over current flags, which cause an channel 0 or 1 driving a too high current to switch off, are latched like the over temperature flags. Those latches are cleared by SPI command HWCR.CL. Please note: The over temperature and over current information is latched twice. When transmitting a clear latch command (HWCR.CL), the error flag is cleared during command transmission of the next SPI frame and ready for latching after the third raising edge of the SCLK signal. As a result, the first standard diagnosis information after a CL command will indicate a failure mode at the previously affected channels although the thermal latches have been cleared already. In case of continuous over load, the error flags are set again immediately because of the over load monitoring signal. 9.2 Load Current Sense Diagnosis There is a current sense signal available at pin IS which provides a current proportional to the load current of one selected channel. The selection is done by a multiplexer which is configured via SPI. Table 6 Operation Modes 1) 1) L = low level, H = high level, Z = high impedance, potential depends on leakage currents and external circuit x = undefined Operation Mode Input Level OUT.OUTn Output Level VOUT Current Sense IIS Error Flag ERRn 2) 2) The error flags are latched until they are transmitted in the standard diagnosis word via SPI SBM DCR.SBM Normal Operation (OFF) L / 0 (OFF-state) GND Z 0 1 Short Circuit to GND GND Z 0 1 Thermal shut down Z Z 0 x Short Circuit to VBB VBB Z 0 0 Open Load Z Z 0 03) 3) If the current sense multiplexer is set to Channel 0 to 3 and DRC.CSOL bit set Inverse Current > VBB Z 0 04) 4) If the current sense multiplexer is set to Channel 0 to 3 Normal Operation (ON) H / 1 (ON-state) ~ VBB IL / kILIS 00 Short Circuit to GND ~ GND Z 1 1 Dynamic Temperature Sensor shut down Z Z 1 x Over Current shut down Z Z 15) 5) The over current latch off flag is set latched and can be cleared by SPI command HWCR.CL x Thermal shut down Z Z 16) 6) The over temperature flag is set latched and can be cleared by SPI command HWCR.CL x Short Circuit to VBB VBB < IL / kILIS 00 Open Load VBB Z0 0 Inverse Current > VBB Z0 0 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |