61 / 84 page ![]() Low-Power, Active Energy, Polyphase AFE ______________________________________________________________________________________ 61 Connections to the Power Source Generally, three-phase power as delivered from the util- ity consists of four wires: three voltage phases and a neutral wire. In one typical three-phase delivery system, measuring from neutral to any phase would read 120V, while measuring from any phase to any other phase would read 208V. Connecting a load so that load cur- rent is taken from phase lines and returned to neutral is called a wye-connected load. Connecting a load so that load current is provided by one phase and returned on another phase is called a delta-connected load. The MAXQ3181 can measure power consumed in either a wye-connected or a delta-connected load. If the load is connected in a wye fashion, the voltage is measured from the neutral lead to each of the phases, and the current measuring device is placed in series with the load, most often in the hot lead. The sensor is not placed in the neutral lead to prevent a customer from defrauding the utility by returning the current to ground rather than neutral. A current sensor placed in the hot lead makes fraud even more difficult. A delta-connected load can have current measured in two possible ways. If it is primarily desirable to know how much power is delivered to the load, one can place the current sensor in the load circuit between two phas- es. But if it is more important to know how much current is being drawn from each supply phase, each current sensor is placed in the line circuit of each single phase. Most utilities are only concerned with the total amount of energy being consumed. If individually accounting for the power delivered by each phase is not a require- ment, it is not necessary to measure all three voltages. Instead, knowing only two voltages and the three cur- rents is all that is necessary to measure total energy usage. There are several ways of doing this. In a wye arrange- ment, one of the phases—usually phase B—–can be considered the voltage reference point instead of neu- tral. Then the voltage measurements can be made from phase A to phase B and from phase C to phase B. By using some simple arithmetic, the power delivered by phase A, phase B, and phase C can be calculated even though only two voltages are available. A second mechanism is to have a delta-connected load, but with one leg—usually the BC leg—split into two equal loads. The point where the load is split is defined as the reference. In this arrangement, it is only necessary to know the voltage between phase C and the split and phase A and the split, since VC = -VA. Finally, there is the connection arrangement in which the load is in a delta configuration with the current sen- sor at each load, but it is still desired to determine how much current is in each supply branch. The MAXQ3181 supports all of these connection arrangements. Sensor Selection The MAXQ3181 supports a variety of voltage and cur- rent sense elements. This section describes the proper- ties of many of these sensing devices. Voltage Sensors Voltage-Divider A voltage-divider is an ideal voltage-sensing element when there is no need for voltage isolation. Modern resistors have virtually no parasitic capacitance or inductance at the frequencies of interest in an electrici- ty meter and have extremely low variation with tempera- ture. When selecting resistors for a voltage-divider, keep the division ratio high enough so that the peak voltage value cannot exceed the maximum allowable input voltage. In the MAXQ3181, the peak input voltage is about 1V; consequently, a divider in the range of 400:1 to 600:1 is ideal. The second consideration is the total power dissipation and voltage hold-off requirements of the resistor. It is tempting to design a 400:1 divider with a 400k Ω resis- tor in series with a 1k Ω resistor, but that would force the 400k Ω resistor to dissipate about 140mW. This is not an excessive amount of power, but if the design is to use small SMT parts, it can handle greater than a 1/10W SMT resistor. It is better to use a series of several small- er components to improve system reliability. Voltage Transformer If isolation is required between the meter electronics and the line, a voltage transformer is required. A volt- age transformer is designed to faithfully transfer an AC voltage applied on the primary side to a sensor on the secondary side. On the primary side, a voltage-divider is used to reduce the voltage to a workable level. On the secondary side, a load resistor is selected so that the current in the transformer windings is safely within the transformer’s linear operating region. Because the impedance seen in the primary side of the transformer is equal to the impedance of the load resis- tor in the secondary circuit plus impedance of the transformer secondary winding at the operating fre- quency, it is easy to calculate the value of the required voltage-divider resistors in the primary side. For exam- ple, assume we want a 500:1 divider ratio and assume |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |