| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAXQ3181-RAN+ bảng dữ liệu(PDF) 56 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAXQ3181-RAN+ bảng dữ liệu(HTML) 56 Page - Maxim Integrated Products |
|
56 / 84 page ![]() Low-Power, Active Energy, Polyphase AFE 56 ______________________________________________________________________________________ OV: The RMS voltage on one or more of the phases over the most recent DSP cycle has exceeded the value set in the OVLVL register. UV: The RMS voltage on one or more of the phases over the most recent DSP cycle has failed to exceed the value set in the UVLVL register. NOZX: Zero crossings were not detected on one or more of the phases. The detection time is defined in the NZX_TIMO register. The resolution for the NZX_TIMO register is the duration of one ADC sam- ple time (nominally 40μs). DCHA: Tells the host processor that the direction of net real energy flow on one of the three phases has changed during the current DSP cycle as compared to the previous DSP cycle. DSPRDY: Indicates the latest DSP cycle has just completed. DSPOR: Indicates that the processing for the previ- ous DSP cycle had not been completed before the current DSP cycle became available for processing. This overflow indication should never be seen in the default configuration; however, under some condi- tions (faster ADC rate, slower CPU clock) the pro- cessing requirements may exceed the number of CPU cycles available for DSP processing. Under these circumstances, the clock rate may be increased, the ADC rate may be reduced (that is, the R_ADCRATE register may be increased). Note that when DSPOR becomes set, all DSP calcu- lations as well as the pulse output are invalidated. The appropriate host response is to take the remedi- al action described above and discard the current set of DSP result values. Each phase has a local register that contains copies of the OC, OV, UV, NOZX, and DCHA bits. Thus, to deter- mine which phase(s) have exception conditions requires four reads: the IRQ_FLAG register to deter- mine which conditions are active that are causing the interrupt to occur, and then a read to A.FLAGS, B.FLAGS, and C.FLAGS to determine which of the phases have the indicated condition. Finally, each phase has a pair of local registers that contain overflow flags for each energy accumulator. If the EOVF bit is set in the IRQ_FLAG register, the host should then read the A.EOVER, B.EOVER, and C.EOVER registers to determine which of the phases have overflow conditions. Overvoltage and Overcurrent Detection The MAXQ3181 detects overvoltage and overcurrent events and can issue interrupt request signals to the master when these events occur. The overvoltage level can be programmed into the OVLVL register, while the overcurrent level is determined by the OCLVL register. Both OVLVL and OCLVL registers represent the bits 23:8 of the VRMS or IRMS registers. Any time the MAXQ3181 detects the RMS-value exceeding a thresh- old level, the OV or OC interrupt flag is set. If enabled, any of these flags issues an interrupt request. All inter- rupt flags are “sticky” bits—the MAXQ3181 never clears them on its own unless a reset occurs. The inter- rupt flags should be cleared by the master by writing the appropriate register. Meter Units to Real Units Conversion All energy calculations, including various threshold checks, are performed internally in fixed format in meter units. Therefore, the threshold values must be supplied by the user in meter units as well. This section summa- rizes how to convert real units (V, A, kWh, W, and kAh) into meter units and vice versa. The conversion factors are based on the settings of tFR, VFS, and IFS, defined by the user’s design. tFR is analog scan frame timing. This parameter is defined by the R_ADCRATE setting and system clock frequency fSYS: tFR = (R_ADCRATE + 1) x 8/fSYS Default conditions are R_ADCRATE = 319, fSYS = 8MHz. VFS is full-scale voltage. This is the input voltage that produces full-scale ADC output; defined by the hard- ware voltage transducer ratio VTR and ADC full-scale input voltage VFSADC: VFS = VFSADC x VTR Default conditions are VFSADC = 1.024V. VTR is design dependent. IFS is full-scale current. This is the input current that produces full-scale ADC output; defined by the hard- ware current transducer ratio ITR and ADC full-scale input voltage VFSADC: IFS = VFSADC x ITR Default conditions are VFSADC = 1.024V. ITR is design dependent. Meter units are defined with respect to the base para- meters as shown in Table 5. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |