| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAXQ3181-RAN+ bảng dữ liệu(PDF) 54 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAXQ3181-RAN+ bảng dữ liệu(HTML) 54 Page - Maxim Integrated Products |
|
54 / 84 page ![]() Low-Power, Active Energy, Polyphase AFE 54 ______________________________________________________________________________________ Regardless of the internal units used, VOLT_CC and AMP_CC can be tailored so that the LSB of the virtual register can be any value. For example, if one wished to have a 32-bit value representing milliamps, one could multiply by a value that scaled the register such that the LSB was 2-16mA. Then, discard the low-order 16 bits. The result is milliamps with 32 bits of precision; thus, the maximum current that could be represented would be 4,294,967,296mA, or just over 4MA. The VOLT_CC and AMP_CC values can be calculated from the full-scale voltage or full-scale current and the desired value of one LSB in the display register: Example: Assume the full-scale current is 102.4A, and that we desire a 1nA LSB. The calculation would pro- vide an AMP_CC value of: 102.4/(224 x 10-9) = 6104 = 0x17D8 Power The MAXQ3181 measures energy. But power is just energy per unit time, and the MAXQ3181 keeps track of the time unit over which energy is accumulated. This is simply the NS value, the fractional number of samples that comprises one DSP cycle. So converting energy to power is as simple as dividing the accumulated energy over one DSP cycle by NS. Multiplying by a conversion constant (PWR_CC) gives power in user-established units. The power registers (PWRP.A, PWRP.B, PWRP.C, PWRS.A, PWRS.B, PWRS.C) are calculated by multiply- ing the accumulated energy (A.ACT, A.APP, B.ACT, B.APP, C.ACT, C.APP) by the conversion coefficient (PWR_CC) and then dividing by NS. The result is the 48-bit average power over the most recent DSP cycle, in units established by the conversion coefficient. The PWR_CC value can be calculated from the full- scale voltage, the full-scale current, and the desired value of one LSB in the display register: Example: For this example, assume the full-scale cur- rent is 102.4A, the full-scale voltage is 558.1V, and that the desired LSB is milliwatts after discarding the 16 LSB; that is, the desired LSB is 2-16 milliwatts. Perform the following calculation: 102.4 x 558.1/(232 x 2-16 x 10-3) = 872 = 0x0368 Power Factor Power factor is calculated as real power divided by apparent power. Apparent power is computed as the product of the RMS voltage and current measurement. The power factor is multiplied by 214 before it is report- ed; thus, unity power factor is given by 16,384 decimal (0x4000). Line Frequency The line frequency is derived directly from the mean NS values over the three phases. It is reported as millihertz; thus, a 50Hz line frequency is reported as decimal 50,000 (0xC350). Energy Energy is read as the net energy directly scaled from the appropriate registers. For example, the energy read from the ENRP.A register (real energy, phase A) is composed of the difference between the A.EAPOS (real energy, positive direction, phase A) and A.EANEG (real energy, negative direction, phase A) registers scaled by the ENR_CC register. Note that the energy registers (ENRP.A, ENRP.B, ENRP.C, ENRP.T, ENRS.A, ENRS.B, ENRS.C, ENRS.T) represent the energy, in every case, since the last over- flow event. For this reason, software must keep track of overflow and make adjustments accordingly when using this register set. To calculate the ENR_CC register value, begin with the full-scale voltage and full-scale current, the frame time, and the desired LSB value for energy. Then perform the following calculation: Example: It is essential to ensure that the correct units are maintained throughout the calculation. In this exam- ple, assume that the full-scale voltage is 558.1V, the full-scale current is 102.4A, the frame time is the default of 320μs, and the desired LSB is 100 milliwatt-hours after the 32 bits are discarded; that is, the LSB is 0.1 x 2-32 watt-hours. Notice, however, that the frame time is given in microseconds and must be converted to hours before the calculation can be performed: 320μs is 88.9 x 10-9 hours. So the calculation proceeds as follows: 102.4 x 558.1 x 88.9 x 10-9/(216 x 0.1 x 2-32) = 3329 = 0x0D01 ENR CC IV t ENR LSB FS FS FR _ _ = ×× × 216 PWR CC IV PWR LSB FS FS _ _ = × × 2 32 VOLT CC V VOLT LSB FS _ _ = × 2 24 AMP CC I AMP LSB FS _ _ = × 2 24 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |