| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAXQ3181-RAN+ bảng dữ liệu(PDF) 63 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAXQ3181-RAN+ bảng dữ liệu(HTML) 63 Page - Maxim Integrated Products |
|
63 / 84 page ![]() Low-Power, Active Energy, Polyphase AFE ______________________________________________________________________________________ 63 The filter coefficient is a signed 16-bit value and can be configured by master. Here Y denotes the global NS value, X denotes individual NS measurements pro- duced by zero-crossing events detected on the phase A, B, or C voltage channel. Note that if all three phase voltages present, the filter above receives three inputs each DSP cycle. The global NS value is used to gener- ate the trigger for DSP processing. Note that the NS value can be configured by the master, which could be necessary if all three voltage signals are lost and no zero-crossings are detected. The line period is then calculated as a product of NS and the scan frame tFR. The reciprocal of this value is the line frequency, which can be obtained as a fixed-point value with 1 LSB = 0.001Hz by reading the LINEFR register. Low-Power Measurement Mode (LOWPM) This mode enables a subset of metering functions while operating from the lower frequency internal RC oscilla- tor to conserve power. The actual system clock fre- quency used is the RC oscillator output frequency divided by 8, which results in a system clock frequency of approximately 1MHz. The parameters provided in the LOWPM are: • Voltage RMS • Current RMS • Ampere-Hour The ampere-hour value is readable from the X.ESF reg- isters (X = A/B/C). Entry to LOWPM mode only occurs at the request of the master. The master must set the LOWPM_E bit (register address 0xC03) to 1 to place the MAXQ3181 into LOWPM mode. Entering LOWPM mode changes the clock frequency, thereby invalidat- ing a number of configuration registers. As a result, the master must immediately reload the configuration regis- ters and filter with new, updated values before metering measurement operations can continue. The master instructs the MAXQ3181 to exit LOWPM mode by reading the LOWPM_X bit (register address 0xC04). Temperature The MAXQ3181 contains a temperature sensor that can be used by host software for any purpose, including compensating power readings for temperature effects. Use the virtual register command (RAWTEMP, 0xC01) to perform a temperature conversion. The MAXQ3181 returns raw ADC reading of voltage produced by the temperature sensor. Conversion from the arbitrary units to useful units (such as degrees Celsius) requires taking one calibration point and storing a conversion constant in the host processor. The conversion constant is simply the value (in absolute degrees) of one LSB. To calculate the LSB value, take a reading at a known temperature and divide the known temperature by the reading. For example, assume you take a reading at room temperature (23°C), and the reading is 0x7F00. The degrees per LSB are then: (23 + 273.15)/0x7F00 = 0.00911K Now, assume at a later time you read the temperature and see it is 0x84F0. To find the temperature in Celsius, multiply by the degrees per LSB and subtract 273.15: 0x84F0 x 0.00911 - 273.15 = 36.8 °C Advanced Calibrations Calibrating Current Offset Ideal hardware should produce a current reading lin- early proportional to the input current. However, due to noise or other factors, the RMS current read by the meter might not be precisely linear. The current offset (X.OFFS_HI, X = A/B/C) can be used to compensate the current channel nonlinearity. Since the MAXQ3181 tracks the input current to deter- mine what linearity compensation factors to use, the user must choose two points (ilo and ihi) comfortably above the low current threshold, and get the X.IRMS current readings (rlo and rhi). Then calculate the Y-inter- cept of the line drawn between the two points, that is, the offset. To calculate the value for the offset register, use the following formula. If LINFRM = 0: If LINFRM = 1: In this equation, ihi and rhi are the applied current and the current reading, respectively, in meter units at the higher of the two reference currents; ilo and rlo are the applied current and the current reading, respectively, in meter units at the lower of the two reference currents. The gain (X.I_GAIN) may require recalibration after the offset register updated. Calibrating Linearity The current channel includes a variable-gain amplifier that introduces a gain of 32 when the current falls below the low current threshold (about 1/32 of full-scale current IFS). Because the gain of the amplifier cannot offs ri i r ii hi lo hi lo lo hi = − − () 2 4 offs ri i r ii hi lo hi lo hi lo = − − 22 2 2 24 2 2 2( ) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |