| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TMS320F28375DPZP bảng dữ liệu(PDF) 144 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMS320F28375DPZP bảng dữ liệu(HTML) 144 Page - Texas Instruments |
|
144 / 222 page ![]() 144 TMS320F28379D, TMS320F28378D, TMS320F28377D TMS320F28376D, TMS320F28375D, TMS320F28374D SPRS880K – DECEMBER 2013 – REVISED NOVEMBER 2018 www.ti.com Submit Documentation Feedback Product Folder Links: TMS320F28379D TMS320F28378D TMS320F28377D TMS320F28376D TMS320F28375D TMS320F28374D Specifications Copyright © 2013–2018, Texas Instruments Incorporated 5.12.2.1 I2C Electrical Data and Timing Table 5-68 shows the I2C timing requirements. Table 5-69 shows the I2C switching characteristics. Table 5-68. I2C Timing Requirements MIN MAX UNIT th(SDA-SCL)START Hold time, START condition, SCL fall delay after SDA fall 0.6 µs tsu(SCL-SDA)START Setup time, Repeated START, SCL rise before SDA fall delay 0.6 µs th(SCL-DAT) Hold time, data after SCL fall 0 µs tsu(DAT-SCL) Setup time, data before SCL rise 100 ns tr(SDA) Rise time, SDA Input tolerance 20 300 ns tr(SCL) Rise time, SCL Input tolerance 20 300 ns tf(SDA) Fall time, SDA Input tolerance 11.4 300 ns tf(SCL) Fall time, SCL Input tolerance 11.4 300 ns tsu(SCL-SDA)STOP Setup time, STOP condition, SCL rise before SDA rise delay 0.6 µs Table 5-69. I2C Switching Characteristics over recommended operating conditions (unless otherwise noted) PARAMETER TEST CONDITIONS MIN MAX UNIT fSCL SCL clock frequency 0 400 kHz tw(SCLL) Pulse duration, SCL clock low 1.3 µs tw(SCLH) Pulse duration, SCL clock high 0.6 µs tw(SP) Pulse duration of spikes that will be suppressed by the input filter 0 50 ns tBUF Bus free time between STOP and START conditions 1.3 µs tv(SCL-DAT) Valid time, data after SCL fall 0.9 µs tv(SCL-ACK) Valid time, Acknowledge after SCL fall 0.9 µs VIL Valid low-level input voltage –0.3 0.3 * VDDIO V VIH Valid high-level input voltage 0.7 * VDDIO VDDIO + 0.3 V VOL Low-level output voltage Sinking 3 mA 0 0.4 V II Input current on pins 0.1 Vbus < Vi < 0.9 Vbus –10 10 µA NOTE To meet all of the I2C protocol timing specifications, the I2C module clock must be configured from 7 MHz to 12 MHz. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |