| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAC7200 bảng dữ liệu(PDF) 256 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MAC7200 bảng dữ liệu(HTML) 256 Page - Freescale Semiconductor, Inc |
|
256 / 976 page ![]() Functional Description MAC7200 Microcontroller Family Reference Manual, Rev. 2 178 Freescale Semiconductor Error information is messaged out in the following format: 11.11.3.2.4 Data Trace Synchronization Messages A Data Trace Write/Read with Sync. Message is messaged via the auxiliary port (provided Data Trace is enabled) for the following conditions (see Table 11-40): • Initial Data Trace Message upon exit from system reset or whenever Data Trace is enabled will be a synchronization message. • Upon returning from a Low Power state, the first Data Trace Message will be a synchronization message. • Upon returning from Debug Mode, the first Data Trace Message will be a synchronization message. • After occurrence of queue overrun (can be caused by any trace message), the first Data Trace Message will be a synchronization message. • After the periodic data trace counter has expired indicating 255 without-sync Data Trace Messages have occurred since the last with-sync message occurred. • Upon assertion of the Event In (EVTI) pin, the first Data Trace Message will be a synchronization message if the EIC bits of the DC Register have enabled this feature. • Upon Data Trace Write/Read after the previous DTM Message was lost due to an attempted access to a secure memory location (for SoCs with security). • Upon Data Trace Write/Read after the previous DTM Message was lost due to a collision entering the FIFO between the DTM Message and two other higher priority messages. Data Trace Synchronization Messages provide the full address (without leading zeros) and insure that development tools fully synchronize with Data Trace regularly. Synchronization messages provide a reference address for subsequent DTMs, in which only the unique portion of the Data Trace address is transmitted. The format for Data Trace Write/Read with Sync. Messages is as follows: Exception conditions that result in Data Trace Synchronization are summarized in Table 11-40. (5 bits) (4 bits) (6 bits) Error Code (00010 / 00111 / 01000) Src. Proc. TCODE (001000) Fixed length = 15 bits Figure 11-41. Error Message Format (1–32 bits) (1–32 bits) (3 bits) (4 bits) (6 bits) Data Value Full Address Data Size Src. Proc. TCODE (001101 or 001110) Max length = 77 bits; Min length = 15 bits Figure 11-42. Data Write/Read with Sync. Message Format |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |