16 / 79 page ![]() Table 6-4. SEL2 HW Mode configuration (continued) SEL2 Connection Configuration 330Ω to IOVDD I2S R or TDM1 Direct Short to IOVDD I2S (L+R)/2 or TDM2 1.2kΩ to GND Left-Justified L or TDM3 1.2kΩ to IOVDD Left-Justified R or TDM4 5kΩ to GND Left-Justified (L+R)/2 or TDM5 5kΩ to IOVDD I2S L or TDM6 24kΩ to GND I2S R or TDM7 24kΩ to IOVDD Reserved Table 6-5. SEL3 HW Mode configuration SEL3 Connection Configuration Direct Short to GND Data valid on rising edge Direct Short to IOVDD Data valid on falling edge Table 6-6. SEL4 HW Mode configuration SEL4 Connection Configuration Direct Short to GND Y-bridge threshold of 80mW Direct Short to IOVDD Y-bridge threshold of 40mW 24kΩ to IOVDD Y-bridge threshold of 1mW 6.3.1.3 Software Power Modes Control and Software Reset When SEL1 pin is shorted to GND, TAS2020 is configured in I2C Mode and can be configured by modifying configuration registers over I2C interface. TAS2020 power state can be controlled using the register MODE[1:0]. Change in any of the MODE settings will not cause the device to lose any of the existing device configuration register settings. Table 6-7. Software Mode Control MODE[1:0] Configuration 00 Device in active mode of operation 01 Reserved 10 (default) Device in software shutdown mode 11 Device in Clock based Active and shutdown mode Active state: When MODE[1:0] is configured as '00', the device enters an active mode of operation with proper power-up sequencing to minimize the click and pop. Software shutdown state: When MODE[1:0] is configured as '10', the device enters software shutdown mode. This mode powers down all analog blocks required to playback audio but does not cause the device to lose register state. If audio is playing when Software Shutdown is asserted, the Class-D will volume ramp down before shutting down. When de-asserted, the Class-D will begin switching and volume ramp back to the programmed digital volume setting. Clock based Active and shutdown state: When MODE[1:0] is configured as '11' the device toggles between Active and Shutdown state based on valid ASI clock signals applied on the ASI input pins, BCLK and FSYNC. When clocks are applied, the device will automatically detect the clock signals and follow proper power-up sequencing to avoid any power-up click and pop. When the audio channels are powered up and the ASI clock is removed, the device will automatically start power-down sequencing and avoid any click and pop. It is TAS2020 SLASFD4A – AUGUST 2024 – REVISED JULY 2026 www.ti.com 16 Submit Document Feedback Copyright © 2026 Texas Instruments Incorporated Product Folder Links: TAS2020 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |