| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
IMX53CEC bảng dữ liệu(PDF) 83 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
IMX53CEC bảng dữ liệu(HTML) 83 Page - Freescale Semiconductor, Inc |
|
83 / 204 page ![]() Electrical Characteristics i.MX53xD Applications Processors for Consumer Products, Rev. 2 Freescale Semiconductor 83 4.7.7 I2C Module Timing Parameters This section describes the timing parameters of the I2C module. Figure 43 depicts the timing of I2C module, and Table 57 lists the I2C module timing characteristics. Figure 43. I2C Bus Timing Table 57. I2C Module Timing Parameters ID Parameter Standard Mode Supply Voltage = 1.65 V–1.95 V, 2.7 V–3.3 V Fast Mode Supply Voltage = 2.7 V–3.3 V Unit Min Max Min Max IC1 I2CLK cycle time 10 — 2.5 — µs IC2 Hold time (repeated) START condition 4.0 — 0.6 — µs IC3 Set-up time for STOP condition 4.0 — 0.6 — µs IC4 Data hold time 01 1 A device must internally provide a hold time of at least 300 ns for I2DAT signal in order to bridge the undefined region of the falling edge of I2CLK. 3.452 2 The maximum hold time has only to be met if the device does not stretch the LOW period (ID no IC5) of the I2CLK signal. 01 0.92 µs IC5 HIGH Period of I2CLK Clock 4.0 — 0.6 — µs IC6 LOW Period of the I2CLK Clock 4.7 — 1.3 — µs IC7 Set-up time for a repeated START condition 4.7 — 0.6 — µs IC8 Data set-up time 250 — 1003 3 A Fast-mode I2C-bus device can be used in a Standard-mode I2C-bus system, but the requirement of Set-up time (ID No IC7) of 250 ns must be met. This automatically is the case if the device does not stretch the LOW period of the I2CLK signal. If such a device does stretch the LOW period of the I2CLK signal, it must output the next data bit to the I2DAT line max_rise_time (IC9) + data_setup_time (IC7) = 1000 + 250 = 1250 ns (according to the Standard-mode I2C-bus specification) before the I2CLK line is released. —ns IC9 Bus free time between a STOP and START condition 4.7 — 1.3 — µs IC10 Rise time of both I2DAT and I2CLK signals — 1000 20 + 0.1Cb 4 4 C b = total capacitance of one bus line in pF. 300 ns IC11 Fall time of both I2DAT and I2CLK signals — 300 20 + 0.1Cb 4 300 ns IC12 Capacitive load for each bus line (Cb) — 400 — 400 pF IC10 IC11 IC9 IC2 IC8 IC4 IC7 IC3 IC6 IC10 IC5 IC11 START STOP START START I2DAT I2CLK IC1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |