31 / 98 page ![]() 13 Floating Blanking Section 5-2 5-2 Floating Blanking !WARNING Use of Fixed Blanking and Floating Blanking will make the MS4800 system less sensitive to objects in the detection zone. Improper use of these features can result in severe injury to personnel. Fixed Blanking may require a hard barrier. Fixed Blanking and Floating Blanking may require an increase in the safety distance. Read the following section carefully. One channel can be obstructed at any location in the detection zone as long as the optical synchronization is maintained. Please refer to chapter 5-4 Opti- cal Synchronization for further details. This means that an object can freely float from one end of the protective field to the other without the MS4800 system entering the MACHINE STOP state. The obstructed channels are not fixed at a single location but "float" through the detection zone. Note Please refer for further information to the FAQ to section 17-6. 5-2-1 Selecting Floating Blanking with selector switches Using the selector switches an authorized user can activate the Floating Blanking function. This allows the system to operate with one obstructed opti- cal beam anywhere within the protected zone. This obstruction is permitted anywhere within the protected zone and is permitted to move over time. After setting the appropriate selector switches, the receiver enters the Power-On Self Test state and if no faults are detected the receiver shall enter the INTER- LOCK or MACHINE RUN condition depending upon the selected operating mode. !WARNING Two-Beam Floating Blanking is not available on the MS4800 system. Floating Blanking Inactive 1 Channel Floating Blanking Active 1 Channel Floating Blanking Active 1 Channel Floating Blanking Active 1 Channel Floating Blanking Active Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 System Response 1 Exception MACHINE STOP 0 Exceptions Machine Run 1 Exception Machine Run 2 Exceptions MACHINE STOP 2 Exceptions MACHINE STOP Clear Optical Channel Optical Channel is obstructed Floating Blanking Effects on Minimum Object Resolution Standard Minimum Object Resolution (No Floating Blanking) Minimum Object Resolution with 1 Beam Blanking 14 mm 24 mm 30 mm 50 mm |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |