| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
L6751C bảng dữ liệu(PDF) 52 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6751C bảng dữ liệu(HTML) 52 Page - STMicroelectronics |
|
52 / 57 page ![]() PMBus support (preliminary) L6751C 52/57 DocID025037 Rev 1 12.3 Input voltage monitoring (READ_VIN) The dedicated PMBus command allows the user to monitor input voltage. By connecting the VIN pin to the input voltage with the recommended resistor values, the L6751C returns the value of the input voltage measured as a voltage (linear format, N = -4). The divider needs to be programmed to have 1.24 V on the pin when VIN = 15.9375 V. According to this, RUP = 118.5 k and RDOWN = 10 k. Errors in defining the divider lead to monitoring errors accordingly. Filter VIN pin locally to GND to increase stability of the voltage being measured. 12.4 Duty cycle monitoring (READ_DUTY) The dedicated PMBus command allows the user to monitor duty cycle for multi-phase with the aim of calculating input current inexpensively (no need for input current-sense resistors). By connecting the PHASE pin to the phase1 PHASE pin, the L6751C returns the value of the duty cycle as a percentage (linear format, N = -2). The divider needs to be programmed to respect absolute maximum ratings for the pin (7 Vmax). According to this, RUP = 5.6 k and RDOWN = 470 . 12.5 Output voltage monitoring (READ_VOUT) The dedicated PMBus command allows the user to monitor output voltage for both sections. The L6751C returns the value of the programmed VID in VID LSBs (i.e. number of LSBs. C8h = 200 dec x 5 mV = 1.000 V). 12.6 Output current monitoring (READ_IOUT) The dedicated PMBus command allows the user to monitor output current for both sections. The L6751C returns the value of the delivered current by reading IMON voltage (same as VR12 register 15h) in amperes (linear format, N = 0). 12.7 Temperature monitoring (READ_TEMPERATURE) The dedicated PMBus command allows the user to monitor the temperature of the power section for multi-phase. The L6751C returns the value of the temperature sensed by NTC connected on the TM/STM pin (the same as VR12 temperature zone) in degrees Celsius (linear format, N = 0). 12.8 Overvoltage threshold setting The dedicated MFR_SPECIFIC command allows the user to program specific thresholds for multi-phase and single-phase sections. The threshold can be programmed according to Table 17. Different thresholds can be configured for multi-phase and single-phase sections. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |