35 / 239 page ![]() ST10F280 Internal Flash memory Doc ID 8673 Rev. 3 35/239 5.3.3 Flash Status Register The Flash Status register is used to flag the status of the Flash memory and the result of an operation. This register can be accessed by Read cycles during the program-Erase Controller operations. The program or erase operation can be controlled by data polling on bit FSB.7 of Status Register, detection of Toggle on FSB.6 and FSB.2, or Error on FSB.5 and Erase Timeout on FSB.3 bit. Any read attempt in Flash during EPC operation will automatically output these five bits. The EPC sets bit FSB.2, FSB.3, FSB.5, FSB.6 and FSB.7. Other bit are reserved for future use and should be masked. Flash Status Address: See note for address Type: R 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 --- -- --- FSB.7 FSB.6 FSB.5 - FSB.3 FSB.2 -- RR R R R FSB.7 Flash Status bit 7: Data Polling Bit Programming Operation: this bit outputs the complement of the bit 7 of the word being programmed, and after completion, will output the bit 7 of the word programmed. Erasing Operation: outputs a ‘0’ during erasing, and ‘1’ after erasing completion. If the block selected for erasure is (are) protected, FSB.7 will be set to ‘0’ for about 100 µs, and then return to the previous addressed memory data value. FSB.7 will also flag the Erase Suspend Mode by switching from ‘0’ to ‘1’ at the start of the Erase Suspend. During Program operation in Erase Suspend Mode, FSB.7 will have the same behaviour as in normal Program execution outside the Suspend mode. FSB.6 Flash Status bit 6: Toggle Bit Programming or Erasing Operations: successive read operations of Flash Status register will deliver complementary values. FSB.6 will toggle each time the Flash Status register is read. The Program operation is completed when two successive reads yield the same value. The next read will output the bit last programmed, or a ‘1’ after Erase operation FSB.6 will be set to‘1’ if a read operation is attempted on an Erase Suspended block. In addition, an Erase Suspend/Resume command will cause FSB.6 to toggle. FSB.5 Flash Status bit 5: Error Bit This bit is set to ‘1’ when there is a failure of Program, block or chip erase operations.This bit will also be set if a user tries to program a bit to ‘1’ to a Flash location that is currently programmed with ‘0’. The error bit resets after Read/Reset instruction. In case of success, the Error bit will be set to ‘0’ during Program or Erase and then will output the bit last programmed or a ‘1’ after erasing FSB.3 Flash Status bit 3: Erase Time-out Bit This bit is cleared by the EPC when the last Block Erase command has been entered to the Command Interface and it is awaiting the Erase start. When the time-out period is finished, after 96 µs, FSB.3 returns back to ‘1’. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |