Back Button 822-1002-C01 Datasheet HTML 8Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 9Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 10Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 11Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 12Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 13Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 14Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 15Page - Magnetrol International, Inc. 822-1002-C01 Datasheet HTML 16Page - Magnetrol International, Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 40 page
background image
50-621 Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches
9
5. Replace housing cover.
6. Apply power to the unit, and proceed with calibration
of instrument as described in Section 2.0, Calibration
beginning on page 10.
NOTE: Be certain to route all power and control wires through conduit
outlet only and run probe wire up through center hole in ampli-
fier housing base.
1.7.3 Relay Wiring Chart
NOTES AND DEFINITIONS:
1. Equipment controlled by the Kotron relays is assumed to
be powered from one source, while the Kotron unit itself is
assumed to be powered from a different source.
2. Fail means a loss of power to the Kotron unit.
3. HLFS (high level fail-safe) means a material level in the
tank which is equal to or above:
a. The setting of a narrow differential point.
b. The higher setting of a wide differential point.
4. LLFS (low level fail-safe) means a material level in the tank
which is equal to or below:
a. The setting of a narrow differential point.
b. The lower setting of a wide differential point.
5. a. When the relay coil is de-energized, a connection is
made between terminals C (common) and NC (nor-
mally closed), and there is no connection between C
and NO (normally open).
b. When the relay coil is energized, a connection is made
between terminals C and NO, and there is no connec-
tion between C and NC.
6. If Relay 1 is being used as a dedicated diagnostic alarm,
the relay will always de-energize upon fault detection.
Kotron
Material
Fail-safe
Relay
Relay Terminals
Power
Level
Coil
CM to NC
CM to NO
High
HLFS
De-energized
Closed
Open
On
LLFS
Energized
Open
Closed
Low
HLFS
Energized
Open
Closed
LLFS
De-energized
Closed
Open
High
HLFS
De-energized
Closed
Open
Fail
LLFS
De-energized
Closed
Open
Low
HLFS
De-energized
Closed
Open
LLFS
De-energized
Closed
Open



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com