| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
705-5100-F21 bảng dữ liệu(PDF) 36 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
705-5100-F21 bảng dữ liệu(HTML) 36 Page - Magnetrol International, Inc. |
|
36 / 52 page ![]() 36 57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™ 7.1.2 Device Status Parameter in the Transducer Block The following table lists the conditions indicated in the Device Status parameter. It also shows the affect the condi- tion has on PV status, Sub-Status and Limit. The first condition is Type Mode. If everything is running normally and there are no Faults or Warnings, then the device indicates it is “OK” an the local display and in Device Status. The next set of conditions is device faults. The device will most likely not be able to measure level correctly if one or more of these conditions occur. The condition will be indi- cated in Device Status and will affect PV Status, Sub-Status and Limit as indicated. The next set of conditions is the device warnings. The con- dition will not jeopardize the level measurement. However, knowledge of the condition may be useful in troubleshooting the device. The following table describes the conditions that can be seen in Device Status: Device Status PV Status Quality PV Sub Status Limit Type Label Bit # Value Mode OK 15 0x00008000 Good Non-Specific Not Limited Fault Default Params 28 0x10000000 Bad Configuration Error Not Limited Fault No End of Ramp 27 0x08000000 Bad Device Failure Constant Limited Fault Lvl<Probe Length 23 0x00800000 Bad Sensor Failure Constant Limited Fault No Fiducial 21 0x00200000 Bad Device Failure Constant Limited Fault Safety Zone FLT 20 0x00100000 Bad Non-Specific Not Limited Fault No Signal 19 0x00080000 Bad Sensor Failure Constant Limited Fault EOP<Probe Length 18 0x00040000 Bad Sensor Failure Constant Limited Fault EOP High 17 0x00020000 Bad Configuration Error Not Limited Fault High Volume Fit 16 0x00010000 Bad Configuration Error High Limited Warning Hi Temperature 11 0x00000800 No Effect No Effect No Effect Warning Lo Temperature 10 0x00000400 No Effect No Effect No Effect Warning Default Cal 9 0x00000200 No Effect No Effect No Effect Warning Initializing 4 0x00000010 Uncertain Initial Value Constant Limited Warning May be Flooded 3 0x00000008 No Effect No Effect High Limited Warning Dry Probe 2 0x00000004 No Effect No Effect Low Limited Warning Weak Signal 1 0x00000002 No Effect No Effect No Effect Warning No Steam Target 6 0x00000040 No Effect No Effect No Effect Display Message Action Comment OK None Normal operating mode. Default Params Internal non-volatile parameters have been defaulted. Consult factory. No End of Ramp No End-of Ramp signal detected. Consult factory. No Fiducial Fiducial signal is not being detected. 1) Check connection between probe and transmitter. 2) Check for moisture on top of probe. 3) Check for damaged gold pin in the high frequency connector. 4) Consult factory. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |