| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAC7200 bảng dữ liệu(PDF) 265 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MAC7200 bảng dữ liệu(HTML) 265 Page - Freescale Semiconductor, Inc |
|
265 / 976 page ![]() Functional Description MAC7200 Microcontroller Family Reference Manual, Rev. 2 Freescale Semiconductor 187 11.11.5.3.3 Single Read Access 1. Initialize the Read/Write Access Address Register (RWA) through the JTAG access method outlined in Section 11.11.5.2, “Read/Write Access to Internal Nexus Registers,” using the Nexus Register Index of 0x9 (see Table 11-21). Configure as follows: — Read Address → 32'hxxxxxxxx (read address) 2. Initialize the Read/Write Access Control/Status Register (RWCS) through the JTAG access method outlined in Section 11.11.5.2, “Read/Write Access to Internal Nexus Registers,” using the Nexus Register Index of 0x7 (see Table 11-21). Configure the bits as follows: — Access Control (AC) → 1'b1 (to indicate start access) —Map Select (MAP) → 3'b000 (primary memory map) — Access Priority (PR) → 2'b00 (lowest priority) — Read/Write (RW) → 1'b0 (read access) — Word Size (SZ) → 3'b0xx (32-bit, 16-bit, 8-bit) — Access Count (CNT) → 14'h0000 or 14'h0001(single access) NOTE Access Count (CNT) of 14'h0000 or 14'h0001 will perform a single access. 3. The Nexus block will then arbitrate for the AHB and the read data will be transferred from the AHB to the RWD Register. When the transfer completed without error (ERR=1'b0), the Nexus block asserts the RDY pin (see Table 11-13 for detail on RDY) and sets the DV bit in the RWCS Register. This indicates that the device is ready for the next access. 4. The data can then be read from the Read/Write Access Data Register (RWD) through the JTAG access method outlined in Section 11.11.5.2, “Read/Write Access to Internal Nexus Registers using the Nexus Register Index of 0xA (see Table 11-21). NOTE Only the RDY pin as well as the DV and ERR bits within the RWCS provide Read/Write Access status to the external development tool. The development tool needs to provide at least one clock after entering the Run-Test-Idle state to ensure that the RDY pin is asserted 11.11.5.3.4 Block Read Access 1. For a block read access, follow Steps 1 and 2 outlined in Section 11.11.5.3.3, “Single Read Access,” to initialize the registers, using a value greater than one (14'h0001) for the CNT field in the RWCS Register. 2. The Nexus block will then arbitrate for the AHB and the read data will be transferred from the AHB to the RWD Register. When the transfer has completed without error (ERR=1'b0), the address from the RWA Register is incremented to the next word size (specified in the SZ field) and the number from the CNT field is decremented. The Nexus block will then assert the RDY pin. This indicates that the device is ready for the next access. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |