21 / 87 page ![]() ____________________________________________________________________________________________ DS3106 19-4629; Rev 3; 5/09 21 of 87 7.7.1.3 Locked State The T0 DPLL state machine can reach the locked state from the prelocked, prelocked 2, or loss-of-lock states when the DPLL has locked to the selected reference for at least 2 seconds (see Section 7.7.5). In the locked state the output clocks track the phase and frequency of the selected reference. If the MCR1.LOCKPIN bit is set, the LOCK pin is driven high when the T0 DPLL is in the locked state. While in the locked state, if the selected reference becomes inactive and an activity alarm is raised (corresponding ACT bit set in the 4 ISR2 register), the selected reference is marked invalid (ICn bit goes low in the VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. If the DPLL is switched to the other input and that input is active, the state machine transitions to the prelocked 2 state. 7.7.1.4 Loss-of-Lock State When the loss-of-lock detectors (see Section 7.7.5) indicate loss-of-phase lock, the state machine immediately transitions from the locked state to the loss-of-lock state. If phase lock is regained during that period for more than 2 seconds while in the loss-of-lock state, the state machine transitions back to the locked state. While in the loss-of-lock state, if the selected reference is becomes inactive, an activity alarm is raised (corresponding ACT bit set in the 14 ISR2 register), the selected reference is marked invalid (ICn bit goes low in the 4 VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. If the DPLL is switched to the other input and that input is active, the state machine transitions to the prelocked 2 state. 7.7.1.5 Prelocked 2 State The prelocked and prelocked 2 states are similar. If phase lock (see Section 7.7.5) is achieved for more than 2 seconds, the state machine transitions to locked mode. While in the prelocked 2 state, if the selected reference is becomes inactive, an activity alarm is raised (corresponding ACT bit set in the 14 ISR2 register), the selected reference is marked invalid (ICn bit goes low in the 4 VALSR1 register), and the LOS pin is asserted. If the input stays inactive for 2 seconds, the state machine transitions to the holdover state. 7.7.1.6 Holdover State The device reaches the holdover state when it declares its selected reference invalid for 2 seconds. During holdover the T0 DPLL is not phase-locked to any input clock but instead generates its output frequency based on previous frequencies while it was locked. When the selected reference becomes active, the state machine immediately transitions from holdover to the prelocked 2 state, and tries to lock to the selected reference. 7.7.1.6.1Automatic Holdover For automatic holdover (FRUNHO = 0 in MCR3), the device can be further configured for instantaneous mode or averaged mode. In instantaneous mode (AVG = 0 in HOCR3), the holdover frequency is set to the DPLL’s current frequency 50ms to 100ms before entry into holdover (i.e., the value of the FREQ field in the FREQ1, FREQ2, and FREQ3 registers). The FREQ field is the DPLL’s integral path and, therefore, is an average frequency with a rate of change inversely proportional to the DPLL bandwidth. The DPLL’s proportional path is not used in order to minimize the effect of recent phase disturbances on the holdover frequency. In averaged mode (AVG = 1 in HOCR3 and FRUNHO = 1 in MCR3), the holdover frequency is set to an internally averaged value. During locked operation the frequency indicated in the FREQ field is internally averaged over a one-second period. The T0 DPLL indicates that it has acquired a valid holdover value by setting the HORDY status bit in MSR4 (latched status). If the T0 DPLL must enter holdover before the one-second average is available, an instantaneous value 50ms to 100ms old from the integral path is used instead. 7.7.1.6.2Free-Run Holdover For free-run holdover (FRUNHO = 1 in MCR3), the output frequency accuracy is generated with the accuracy of the external oscillator frequency. The actual frequency is the frequency of the external oscillator plus the value of the MCLK offset specified in the MCLKFREQ field in registers MCLK1 and MCLK2 (see Section 7.3). When MCR3.FRUNHO is set the HOCR3:AVG bit is ignored. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |