| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
M16C/29 bảng dữ liệu(PDF) 104 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/29 bảng dữ liệu(HTML) 104 Page - Renesas Technology Corp |
|
104 / 499 page ![]() 9. Interrupts p u o r G 9 2 / C 6 1 M page 80 8 5 4 f o 7 0 0 2 , 0 3 .r a M 2 1 . 1 . v e R 2 1 1 0 - 1 0 1 0 B 9 0 J E R Interrupt sources _______ Watchdog timer, NMI, Oscillation stop and re-oscillation detection, Low volage detection _________ Software, address match, DBC, single-step 9.4.2 Variation of IPL when Interrupt Request is Accepted When a maskable interrupt request is accepted, the interrupt priority level of the accepted interrupt is set in the IPL. When a software interrupt or special interrupt request is accepted, one of the interrupt priority levels listed in Table 9.5 is set in the IPL. Shown in Table 9.5 are the IPL values of software and special interrupts when they are accepted. Table 9.5 IPL Level That is Set to IPL When A Software or Special Interrupt Is Accepted Figure 9.6 Interrupt response time 9.4.1 Interrupt Response Time Figure 9.6 shows the interrupt response time. The interrupt response or interrupt acknowledge time denotes time from when an interrupt request is generated till when the first instruction in the interrupt routine is executed. Specifically, it consists of the time from when an interrupt request is generated till when the instruction then executing is completed ((a) in Figure 9.6) and the time during which the inter- rupt sequence is executed ((b) in Figure 9.6). Instruction Interrupt sequence Instruction in interrupt routine Time Interrupt response time (a) (b) Interrupt request acknowledged Interrupt request generated (a) The time from when an interrupt request is generated till when the instruction then executing is completed. The length of this time varies with the instruction being executed. The DIVX instruction requires the longest time, which is equal to 30 cycles (without wait state, the divisor being a register). (b) The time during which the interrupt sequence is executed. For details, see the table below. Note, however, that the values in this table must be increased 2 cycles for the DBC interrupt and 1 cycle for the address match and single-step interrupts. Interrupt vector address Even Even Odd Odd SP value Even Odd Even Odd Without wait 18 cycles 19 cycles 19 cycles 20 cycles IPL setting 7 No change |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |