| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
M16C/29 bảng dữ liệu(PDF) 333 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/29 bảng dữ liệu(HTML) 333 Page - Renesas Technology Corp |
|
333 / 499 page ![]() 17. CAN Module p u o r G 9 2 / C 6 1 M page 309 8 5 4 f o 7 0 0 2 , 0 3 .r a M 2 1 . 1 . v e R 2 1 1 0 - 1 0 1 0 B 9 0 J E R 17.10 Reception and Transmission Configuration of CAN Reception and Transmission Mode Table 17.3 shows configuration of CAN reception and transmission mode. Table 17.3 Configuration of CAN Reception and Transmission Mode TrmReq, RecReq, Remote, RspLock, RemActive, RspLock: Bits in the C0MCTLj register (j = 0 to 15) When configuring a slot as a reception slot, note the following points. (1) Before configuring a slot as a reception slot, be sure to set the C0MCTLj register (j = 0 to 15) to 0016. (2) A received message is stored in a slot that matches the condition first according to the result of reception mode configuration and acceptance filtering operation. Upon deciding in which slot to store, the smaller the number of the slot is, the higher priority it has. (3) In normal CAN operating mode, when a CAN module transmits a message of which ID matches, the CAN module never receives the transmitted data. In loop back mode, however, the CAN module receives back the transmitted data. In this case, the module does not return ACK. When configuring a slot as a transmission slot, note the following points. (1) Before configuring a slot as a transmission slot, be sure to set the C0MCTLj registers to 0016. (2) Set the TrmReq bit in the C0MCTLj register to 0 (not transmission slot) before rewriting a transmission slot. (3) A transmission slot should not be rewritten when the TrmActive bit in the C0MCTLj register is 1 (transmitting). If it is rewritten, an undefined data will be transmitted. TrmReq RecReq Remote RspLock Communication mode of the slot 00 -- Communication environment configuration mode: configure the communication mode of the slot. 0 1 0 0 Configured as a reception slot for a data frame. 1 0 1 0 Configured as a transmission slot for a remote frame. (At this time the RemActive = 1.) After completion of transmission, this functions as a reception slot for a data frame. (At this time the RemActive = 0.) However, when an ID that matches on the CAN bus is detected before remote frame transmission, this immediately functions as a reception slot for a data frame. 1 0 0 0 Configured as a transmission slot for a data frame. 0 1 1 1/0 Configured as a reception slot for a remote frame. (At this time the RemActive = 1.) After completion of reception, this functions as a transmission slot for a data frame. (At this time the RemActive = 0.) However, transmission does not start as long as RspLock bit remains 1; thus no automatic response. Response (transmission) starts when the RspLock bit is set to 0. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |