53 / 82 page ![]() 4. Operating characteristics 52 Economical long-life light sources with plug-in bases. Compact Fluorescent Lamps OSRAM DULUX® Technical Guide The following table shows the permitted maximum temperatures on OSRAM DULUX® lamps. Exceeding one or more of the maximum values specified here will lead to: • a noticeable reduction in lamp life • and/or damage to the CCG or ECG • and/or damage to the lamp base and the luminaire holder. In the case of OSRAM DULUX® S, D, T (without amalgam), L and F the limit value of 100 ºC at measuring point 3 (cold spot) should not be exceeded. Exceeding this limit value may cause the lamp to fail. At cold spot temperatures above the optimum (see table 4.8) there are changes in the electrical and photometric data of the lamps (the luminous flux is no longer at 100 %). The limit value at measuring point 1 is 140 ºC for OSRAM DULUX® lamps with and without amalgam. This maximum value was defined as part of the IEC standard for safety reasons. Exceeding this value leads to softening of the plastic base and dis- colouration of the base material. 4.8.1 Maximum temperatures for DULUX®-Lamps Measuring point 0 1 2(1) 3(2) limit values As per As per EN 60901 EN 61199 OSRAM DULUX® 2-pin (CCG operation) 90 °C 140 °C 190 °C 100 °C OSRAM DULUX® 4-pin (ECG operation) – 140 °C 190 °C 100 °C OSRAM DULUX® IN 2-pin (CCG operation) 90 °C 140 °C 190 °C – OSRAM DULUX® IN 4-pin (ECG operation) – 140 °C 190 °C – 1) Measuring point 2 on the glass tube near to the filament is the hottest point on the lamp. Measurements are taken 5 mm from the edge of the base. 2) Maximum limit value of the mercury vapour pressure (see 1.4) On amalgam lamps (OSRAM DULUX® T and T/E...IN), the cold spots are not at the bend in the lamp but in the lower half of the discharge tube inside the base. As far as the luminous flux/temperature curve is concerned, it is not the value at measuring point 3 that is relevant but at the amalgam measuring point inside the base. The optimum amalgam temperature at the measuring point (amalgam reservoir) is between 85 ºC and 115 ºC. This temperature can be measured only with specially prepared lamps. Undershooting or overshooting the temperature range will lead to a reduction in lamp power and luminous flux. Measuring point 1 (IEC measuring point) is not relevant for determining the amalgam temperature and should not be used for this purpose. In addition, any information from ECG manufacturers regarding the permissible limit values at temperature measuring point Tc on the ECG must be observed. If these limit values are exceeded the life of the ECG will be reduced. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |