36 / 82 page ![]() OSRAM DULUX® S, D and T lamps with a two-pin base have an integrated glow star- ter and are suitable for CCG operation. OSRAM DULUX® L and F lamps with four-pin bases do not have an integrated glow starter and require an external starter (see 6.3) if they are to be operated with conventional control gear (18 W to 36 W). It is recommended that only suitable lamp/CCG combinations for single and series circuits be used. The system data (lamp + CCG) is shown in the table in 3.2.1. Circuit diagrams are included in the current OSRAM Lighting Programme. 35 Economical long-life light sources with plug-in bases. Compact Fluorescent Lamps OSRAM DULUX® Technical Guide 3 Circuits 3.1 Operation with electronic control gear (ECG) OSRAM DULUX® S/E, D/E and T/E lamps and OSRAM DULUX® L 40, 55 W and 80 W lamps with four-pin bases have been designed to operate with electronic control gear only. OSRAM DULUX® L and F 18, 24 and 36 W can be operated with either electronic or conventional control gear. To ensure safe operation of both the lamp and the ECG, the wiring between the out- puts of the ECG and the terminals on the lampholder(s) must be correct. This applies not only to two-lamp arrangements but also to single-lamp configurations. Certain cables from the ECG to the lamp or lamps („hot ends“) should be kept as short as possible to avoid problems with radio interference. This means one should choose an asymmetrical mounting location in the luminaire to increase the length of the low- potential cables if you can thereby shorten the lamp cables carrying high potential. The correct circuit layout is generally printed on the ECG casing. Check with the ECG manufacturer to establish which terminals are the „hot ends“. This information may be shown on the casing (e.g. „keep wires x and y short“). With dimmable ECGs the length of the control cable(s) and the way in which they are laid also play a role. For further information on this topic please consult the OSRAM QUICKTRONIC® technical guides or visit www.osram.com. Another important factor with ECGs is the tc measuring point on the casing. The tem- perature indicated here must not be exceeded during operation otherwise the unit will fail prematurely. A prominent characteristic of electronic control gear, and one that applies to most units (see information on the casing) is whether or not it is suitable for dc operation (for approximately the same rms values for AC and DC). In many cases, a DC-compa- tible ECG can also be used in emergency lighting systems. The relevant regulations governing emergency lighting must be observed. QUICKTRONIC® control gear from OSRAM is suitable for emergency lighting in accordance with VDE 0108. Information from the manufacturers regarding circuits (circuit diagrams) can generally be found on the casing cover. For further information on permissible lamp/ECG combinations and system data please consult the latest edition of the OSRAM Lighting Programme or visit www.osram.com. 3. Circuits 3.2 Operation with conventional control gear (CCG) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |