52 / 82 page ![]() Measuring Description Max.temp. point 0 This point is located at the bottom of the base and is determined by 90°C1) the thermal load capacity of the glow starter installed in the bases of according to two-pin lamps for conventional operation. It is therefore relevant only EN 60901 for these lamps (OSRAM DULUX® S, D, T and T IN). 1 The hottest point on the surface of the base on a line which on G23, 140°C2) IEC 2G7 bases (OSRAM DULUX® S and OSRAM DULUX® S/E) is 8 mm according to measuring and on G24, GX24, 2G10 and 2G11 bases (OSRAM DULUX® D, D/E, EN 61199 point T, T/E, L and F) 12 mm from the reference plane in the direction of the Information glass bulb. The limit value for this measuring point has been defined for luminaire in the relevant standard for safety reasons. (If this maximum design as temperature is exceeded the plastic base may start to soften per IEC. (applies to end of life).) 2 Measuring point 2 at the glass tube near the filament is the hottest max. 190 °C Electrode point on the lamp. Measurements are taken 5 mm from the edge of measuring the base. point 3 Applies only to OSRAM DULUX® 2-pin and OSRAM DULUX® 4-pin In CCG and Cold spot lamps without amalgam. Corresponds to the cold spot for base-up ECG operation measuring burning position and a free-burning lamp. In certain circumstances and max. 100 °C point with other burning positions in the luminaire, however, the cold spot (approx. 60 % may be somewhere other than measuring point 3. luminous flux) Exceeding the maximum permitted temperature has a considerable optimum 40°– impact on the electrical and photometric data of the lamp and will 50°C (= 100% cause the lamp to fail. luminous flux) Amalgam Amalgam lamps: The measuring point for amalgam lamps is 85°–115°C measuring on the lamp glass of the amalgam reservoir inside the lamp base. (= 90 % point This temperature can be measured only with specially prepared lamps. luminous flux) 1) Measuring conditions: 25°C ambient temperature, draught free air Reference ballast Supply voltage UV = 1.06 x Urated 2) Measuring conditions: Short-circuited starter 25°C ambient temperature, draught free air Supply voltage UV = 1.1 x Urated Reference ballast 51 DULUX® S DULUX® S/E DULUX® D DULUX® T DULUX® L DULUX® F DULUX® D/E DULUX® T/E Temperature measuring points: 1 0 2 3 0 1 2 3 1 2 1 2 3 0 1 2 3 1 2 3 4. Operating characteristics Economical long-life light sources with plug-in bases. Compact Fluorescent Lamps OSRAM DULUX® Technical Guide 4.8 Lamp temperatures and limiting values Temperature measuring points are defined for OSRAM DULUX® lamps. The temperatures at these points must be within the thresholds for the safe and reliable operation of the lamps. The following limit temperatures must not be exceeded at these points even under adverse installation conditions (in the luminaire, high room temperatures) and at high supply voltages: 3 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |