DL2482 bảng dữ liệu(PDF) 67 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
DL2482 bảng dữ liệu(HTML) 67 Page - OSRAM GmbH |
|
67 / 82 page ![]() 7.2 Operating position 7. Measuring OSRAM DULUX® compact fluorescent lamps 66 Economical long-life light sources with plug-in bases. Compact Fluorescent Lamps OSRAM DULUX® Technical Guide Free-burning OSRAM DULUX® lamps are generally measured in the base-up position, although according to the IEC the reference burning position for OSRAM DULUX® L and OSRAM DULUX® F lamps is horizontal. The base-up position is chosen because the measurements are easier to take and the results are more reliable since the mer- cury remains at the cold spot at the bottom even when the lamp is moved. With lamps in the horizontal burning position, the mercury shifts as soon as the lamp is moved, which destabilises the lamp. The difference in luminous flux between the base-up and horizontal operating positi- ons at constant lamp output for OSRAM DULUX® S, S/E, D, D/E, T, T/E is no more than 1 to 2 %. Deviations of 10 to 20 % can be expected for OSRAM DULUX® T IN and T/E IN lamps between base up and horizontal operating position. Burnt-in and stabilised OSRAM DULUX® lamps provide reproducible photometric data at constant ambient temperature and in an unchanged operating position. Fluctuations are less than 1 % of the upper range value. All the cables, control gear and instruments must be arranged, and if necessary shiel- ded, so that there is no chance of interference from external fields. Use instruments which will supply the level of accuracy required in the measured values. Recommendations: Instruments: Rms instruments (true RMS) Accuracy: ±0,2% of the measuring range Area of application Frequency: 0-500 Hz (CCG) scanning rate 0-400 kHz (ECG) scanning rate Crest factor: > 2 (CCG) > 3 (ECG) Lamp supply: Supply voltage: Depending on the lamp and control gear (CCG, ECG or reference device) Stability: ± 0,2% during the measurement Total harmonic distortion: < 3% Suitable supply: - Noise-free mains - Electronically regulated stabilisers - Rotary measuring generators - Electronic generators The apparent power of the supply unit should be five times the rated system power. The luminous flux and hence the luminous efficacy of OSRAM DULUX® lamps depends on the temperature. To achieve optimum operating conditions for the lamp in the luminaire, it is therefore essential to know either the ambient temperature in the vicinity of the lamp or the cold spot temperature directly on the lamp. 7.3 Constant photometric values 7.4 Electrical measurements 7.5 Temperature measurement |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |