40 / 64 page ![]() LM5064 SNVS718E – JUNE 2011 – REVISED FEBRUARY 2013 www.ti.com MANUFACTURER SPECIFIC PMBUS™ COMMANDS MFR_SPECIFIC_00: READ_VAUX (D0h) The READ_VAUX command will report the 12-bit ADC measured auxiliary voltage. Voltages greater than or equal to 2.97V to VEE will be reported at plus full scale (0FFFh). Voltages less than or equal to 0V referenced to VEE will be reported as 0 (0000h). To read data from the READ_VAUX command, use the PMBus Read Word protocol. Table 22. READ_VAUX Register Value Meaning Default 0h – 0FFFh Measured value for VAUX input 0000h MFR_SPECIFIC_01: MFR_READ_IIN (D1h) The MFR_READ_IIN command will report the 12-bit ADC measured current sense voltage. To read data from the MFR_READ_IIN command, use the PMBus Read Word protocol. Reading this register should use the coefficients shown in Table 41. Please see the section on coefficient calculations to calculate the values to use. Table 23. MFR_READ_IIN Register Value Meaning Default 0h – 0FFFh Measured value for input current sense 0000h voltage MFR_SPECIFIC_02: MFR_READ_PIN (D2h) The MFR_READ_PIN command will report the upper 12 bits of the VIN x IIN product as measured by the 12-bit ADC. To read data from the MFR_READ_PIN command, use the PMBus Read Word protocol. Reading this register should use the coefficients shown in Table 41. Please see the section on coefficient calculations to calculate the values to use. Table 24. MFR_READ_PIN Register Value Meaning Default 0h – 0FFFh Value for input current x input voltage 0000h MFR_SPECIFIC_03: MFR_IN_OC_WARN_LIMIT (D3h) The MFR_IIN_OC_WARN_LIMIT PMBus command sets the input over-current warning threshold. In the event that the input current rises above the value set in this register, the IIN over-current flags are set in the respective registers and the SMBA is asserted. To access the MFR_IIN_OC_WARN_LIMIT register, use the PMBus Read/Write Word protocol. Reading/writing to this register should use the coefficients shown in Table 41. Table 25. MFR_IIN_OC_WARN_LIMIT Register Value Meaning Default 0h – 0FFEh Value for input over-current warn limit 0FFFh 0FFFh Input over-current warning disabled n/a 40 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated Product Folder Links: LM5064 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |