công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

LM5064PMH/NOPB bảng dữ liệu(PDF) 37 Page - Texas Instruments

tên linh kiện LM5064PMH/NOPB
Giải thích chi tiết về linh kiện  LM5064 Negative Voltage System Power Management and Protection IC with PMBus
PDF  64 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  TI2 [Texas Instruments]
Trang chủ  https://www.ti.com
Logo TI2 - Texas Instruments

LM5064PMH/NOPB bảng dữ liệu(HTML) 37 Page - Texas Instruments

Back Button LM5064PMH/NOPB Datasheet HTML 33Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 34Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 35Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 36Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 37Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 38Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 39Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 40Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 41Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 64 page
background image
LM5064
www.ti.com
SNVS718E – JUNE 2011 – REVISED FEBRUARY 2013
STATUS_CML (7Eh)
The STATUS_CML is a standard PMBus command that returns the value of a number of flags related to
communication faults. Accesses to this command should use the PMBus read byte protocol. To clear bits in this
register, a CLEAR_FAULTS command should be issued.
Table 14. STATUS_CML Definitions
Bit
NAME
Default
7
Invalid or unsupported command received
0
6
Invalid or unsupported data received
0
5
Packet Error Check failed
0
4
Not supported, always 0
0
3
Not supported, always 0
0
2
Not supported, always 0
0
1
Miscellaneous communications fault has occurred
0
0
Not supported, always 0
0
STATUS_MFR_SPECIFIC (80h)
The STATUS_MFR_SPECIFIC command is a standard PMBus command that contains manufacturer specific
status information. Accesses to this command should use the PMBus read byte protocol. To clear bits in this
register, the underlying fault should be removed and a CLEAR_FAULTS command should be issued.
Table 15. STATUS_MFR_SPECIFIC Definitions
Bit
Meaning
Default
7
Circuit breaker fault
0
6
Ext. MOSFET shorted fault
0
5
Not Supported, Always 0
0
4
Defaults loaded
1
3
Not supported: Always 0
0
2
Not supported: Always 0
0
1
Not supported: Always 0
0
0
Not supported: Always 0
0
READ_VIN (88h)
The READ_VIN command is a standard PMBus command that returns the 12-bit measured value of the input
voltage. Reading this register should use the coefficients shown in Table 41. Accesses to this command should
use the PMBus read word protocol. This value is also used internally for the VIN Over and Under-Voltage
Warning detection.
Table 16. READ_VIN Register
Value
Meaning
Default
0h – 0FFFh
Measured value for VIN
0000h
Copyright © 2011–2013, Texas Instruments Incorporated
Submit Documentation Feedback
37
Product Folder Links: LM5064



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com