27 / 35 page ![]() WM9707 Production Data w PD Rev 4.1 June 2006 27 POWERDOWN CONTROL/STATUS REGISTER (INDEX 26h) This read/write register is used to program Powerdown states and monitor subsystem readiness. The lower half of this register is read only status, a 1 indicating that the subsection is ready. Ready is defined as the subsection able to perform in its nominal state. When this register is written the bit values that come in on AC-link will have no effect on read only bits 0 to 7. When the AC-link CODEC Ready indicator bit (SDATAIN slot 0, bit 15) is a 1 it indicates that the AC- link and the WM9707 control and status registers are in a fully operational state. The AC’97 controller must further probe this Powerdown Control/Status Register to determine exactly which subsections, if any, are ready. READ BIT FUNCTION REF VREFs up to nominal level ANL Analogue mixers, etc ready DAC DAC section ready to accept data ADC ADC section ready to transmit data Table 11 Powerdown Status Register Function The powerdown modes are as follows. The first three bits are to be used individually rather than in combination with each other. The last bit PR3 can be used in combination with PR2 or by itself. PR0 and PR1 control the PCM ADCs and DACs only. PR6 is not supported by the WM9707. WRITE BIT FUNCTION PR0 PCM in ADCs and input Mux Powerdown PR1 PCM out DACs Powerdown PR2 Analogue mixer Powerdown (VREF still on) PR3 Analogue mixer Powerdown (VREF off) PR4 Digital interface (AC-link) Powerdown (external clock off) PR5 Internal clock disable PR6 HP amp Powerdown – not supported EAPD External amplifier Powerdown Table 12 Powerdown Control Register Function PR0 = 1 PR1 = 1 PR2 = 1 PR4 = 1 PR0 = 0 AND ADC = 1 DEFAULT READY = 1 COLD RESET WARM RESET PR2 = 0 AND ANL = 1 PR1 = 0 AND DAC = 1 ADCs OFF PR0 DACs OFF PR1 ANALOGUE OFF PR2 OR PR3 DIGITAL I/F OFF PR4 SHUT OFF CODA LINK NORMAL Figure 16 An Example of the WM9707 Powerdown/Powerup Flow Figure 16 illustrates one example procedure to do a complete Powerdown of the WM9707. From normal operation sequential writes to the Powerdown Register are performed to Powerdown the WM9707 a piece at a time. After everything has been shut off (PR0 to PR3 set), a final write (of PR4) can be executed to shut down the WM9707’s digital interface (AC-link). |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |