| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
WM9707SCFT/V bảng dữ liệu(PDF) 22 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM9707SCFT/V bảng dữ liệu(HTML) 22 Page - Wolfson Microelectronics plc |
|
22 / 35 page ![]() WM9707 Production Data w PD Rev 4.1 June 2006 22 SYNC BITCLK SDATAIN CODEC READY SLOT (1) SLOT (2) WM9703 SAMPLES SYNC ASSERTION HERE AC'97 CONTROLLER SAMPLES FIRST SDATA_IN BIT OF FRAME HERE END OF PREVIOUS AUDIO FRAME Figure 15 Start of an Audio Input Frame A new audio input frame begins with a low to high transition of SYNC as shown in Figure 15. SYNC is synchronous to the rising edge of BITCLK. On the immediately following falling edge of BITCLK, AC’97 samples the assertion of SYNC. This falling edge marks the time when both sides of AC-link are aware of the start of a new audio frame. On the next rising of BITCLK, AC’97 transitions SDATAIN into the first bit position of slot 0 (“CODEC Ready” bit). Each new bit position is presented to AC-link on a rising edge of BITCLK, and subsequently sampled by the AC’97 Controller on the following falling edge of BITCLK. This sequence ensures that data transitions and subsequent sample points for both incoming and outgoing data streams are time aligned. SDATAIN’s composite stream is MSB justified (MSB first) with all non-valid bit positions (for assigned and/or unassigned time slots) stuffed with 0s by the WM9707. SDATAIN should be sampled on the falling edges of BITCLK. SLOT 1: STATUS ADDRESS PORT The status port is used to monitor status for the WM9707 functions including, but not limited to, mixer settings, and power management. Audio input frame slot 1 echoes the control register index, for historical reference, for the data to be returned in slot 2. (Assuming that slots 1 and 2 had been tagged valid by the WM9707 during slot 0). STATUS ADDRESS PORT BIT ASSIGNMENTS: Bit (19) RESERVED (stuffed with 0s) Bit (18:12) Control register index (echo of register index for which data is being returned) Bit (11:2) Variable sample rate SLOTREQ bits. Bit (1:0) RESERVED (stuffed with 0s) The first bit (MSB) generated by the WM9707 is always stuffed with a 0. The following 7 bit positions communicate the associated control register address. The next 10 bits support the AC’97 Rev 2.1 variable sample rate signalling protocol, and the trailing 2 bit positions are stuffed with 0s by AC’97. SLOT 2: STATUS DATA PORT The status data port delivers 16-bit control register read data. Bit (19:4) Control register read data (stuffed with 0s if tagged invalid by WM9701) Bit (3:0) RESERVED (stuffed with 0s) If slot 2 is tagged invalid by the WM9707, then the entire slot will be stuffed with 0s by the WM9707. SLOT 3: PCM RECORD LEFT CHANNEL Audio input frame slot 3 is the left channel output of the WM9707’s input Mux, post-ADC. The WM9707 sends out its ADC output data (MSB first), and stuffs any trailing non-valid bit positions with 0s to fill out its 20-bit time slot. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |