| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
BQ76PL455APFCT bảng dữ liệu(PDF) 59 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ76PL455APFCT bảng dữ liệu(HTML) 59 Page - Texas Instruments |
|
59 / 125 page ![]() 59 bq76PL455A www.ti.com SLUSCL0A – SEPTEMBER 2016 – REVISED OCTOBER 2016 Product Folder Links: bq76PL455A Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated For details on how to interpret the response, refer to Register Details. A simplified overview of the meaning of the data bytes in this example is in the following table. BYTE (HEX) BYTE (BINARY) DESCRIPTION A2 1 010 0 001 Command frame, Group Write with Response = REQ_TYPE, 8-bit Register Addressing, 2 data bytes = DATA_SIZE 01 00000001 Target is Group ID = 01 03 00000011 Target Register = 03 (Command Channel Select Register) 02 00000010 Address of highest device in target group 03 00000011 Number of Data Bytes – 1 expected in response (4 bytes in this example) 49 01001001 CRC 44 01000100 CRC The command frame in this example will generate a response frame from each of the two devices targeted by the command frame. Each response frame will contain data stored in the Command Channel Select register of the responding bq76PL455A. The response frame from the bq76PL455A at the highest address in the addressed group will arrive first. If the stored data were FFFF8000 (hex) for the device at Device Address 02 in Group 01 and the data were FFFF0100 (hex) for the device at Device Address 01 in Group ID 01, then the response frames would be as in the following table. 7 6 5 4 3 2 1 0 Response Frame Init 0 0000011 (binary) Data FF Data FF Data 80 Data 00 CRC (MSB) 25 CRC (LSB) E4 7 6 5 4 3 2 1 0 Response Frame Init 0 0000011 (binary) Data FF Data FF Data 01 Data 00 CRC (MSB) 45 CRC (LSB) B4 The second of the two response frames will arrive immediately after the first response frame, so the response will typically appear to be one continuous response. Therefore, it is important to remember that each responding device will respond with a complete response frame with its own Frame Initialization byte, data bytes, and CRC bytes. 7.5.3.3.4 Configuration 4: Group Write with Response to Non-Command Register NOTE This configuration uses one byte for addressing and response size. As in the example for Configuration 3, the sample command frame in this example will read the value currently stored in the Command Channel Select (address 3–6) register, but the message to do so is one byte shorter. The expected response frames would be the same as in the example for Configuration 3. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |