22 / 92 page ![]() 14.0 SMBus Interface (Continued) 14.5.4 Read Operations The LM93 uses the following SMBus read protocols. 14.5.4.1 Read Byte In the LM93, the read byte protocol is used to read a single byte of data from a register. In this operation the master device receives a single byte from a slave device, as follows: 1. The master device asserts a START condition. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK. 4. The master sends a register address. 5. The slave asserts an ACK. 6. The master sends a Repeated START. 7. The master sends the slave address followed by the read bit (high). 8. The slave asserts an ACK. 9. The master receives a data byte and asserts a NACK. 10. The master asserts a STOP condition and the transaction ends. 1 2 34 567 89 10 S Slave Address W A Register Address A S Slave Address R A Data Byte /A P 14.5.4.2 Read Word In the LM93, the read word protocol is used to read two bytes of data from a register or two consecutive registers. In this operation the master device reads two bytes from a slave device, as follows: 1. The master device asserts a START condition. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK. 4. The master sends a register address. 5. The slave asserts an ACK. 6. The master sends a Repeated START. 7. The master sends the slave address followed by the read bit (high). 8. The slave asserts an ACK. 9. The master receives the Low data byte and asserts an ACK. 10. The master receives the High data byte and asserts a NACK. 11. The master asserts a STOP condition and the transaction ends. 1 2 34 567 89 10 11 S Slave Address W A Register Address A S Slave Address R A Data Byte Low A Data Byte High /A P 14.5.4.3 SMBus Block-Write Block-Read Process Call This transaction is used to read a block of data from the LM93. Below is the sequence of events that occur in this transaction: 1. The master device asserts a START condition. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK. 4. The master sends a command code that tells the slave device to expect a block read (F1h) and the slave asserts ACK. 5. The master sends the Byte Count for this write which is 2 and the slave asserts ACK. 6. The master sends the Start Register Address for the block read and the slave asserts the ACK. 7. The master sends the Byte Count (1-32) for the block read processes call and the slave asserts ACK. 8. The master asserts a repeat START condition. 9. The master sends the 7-bit slave address followed by the read bit (high). 10. The slave asserts ACK. 11. The master receives a byte count data byte that tells it how many data bytes will received. This field reflects the number of bytes requested by the Byte Count transmitted to the LM93. The SMBus specification allows a maximum of 32 data bytes to be received in a block read. Then master asserts ACK. www.national.com 22 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |