| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AN3985 bảng dữ liệu(PDF) 64 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3985 bảng dữ liệu(HTML) 64 Page - STMicroelectronics |
|
64 / 105 page ![]() LRIxK layer AN3985 64/105 Doc ID 022255 Rev 2 LRIxK_Lock_Kill function This function sends, through the CR95HF, a lock kill command to an LRIxK contactless tag present in the RF field or designated by its UID. Note: The kill code written previously is locked by the LRIxK contactless tag and, once done, the kill code cannot be changed. LRIxK_Inventory_Initiated function This function sends, through the CR95HF, an initiate command to an LRIxK contactless tag present in the field or designated by its UID. On receiving the initiate command, the LRIxK contactless tag sets the internal initiate flag (to send an inventory initiated command) and returns its UID and its DSFID. Table 110. LRIxK_Lock_Kill function description Prototype u8 LRIxK_Lock_Kill(ISO15693_Tag* MyTag, u8 Request_flags, u8* Tag_UID); Input parameter Request_flags: option flag to indicate the parameters to use for the flag response and if UID is present (addressed) Tag_UID: pointer on the UID of the tag Output parameter MyTag: pointer on the structure that contains the tag response Return parameter LRIxK_ERROR_CODE: The command failed. Either there is no tag or the tag did not manage to perform the request. LRIxK_ERROR_REQUEST_FLAGS_CODE: The inventory flag is set. LRIxK_COMMAND_SUCCESS_CODE: The tag answered the command. Table 111. LRIxK_Inventory_Initiated function description Prototype u8 LRIxK_Inventory_Initiated(ISO15693_Tag* MyTag, const u8 Request_flags, const u8 Tag_AFI, const u8 MaskLength, const u8* Mask, u8* Inventory_16_slots_Nb_UID_Retrieved); Input parameter Request_flags: option flag to indicate the parameters to use for the flag response (1) Tag_AFI: the optional AFI to select a tag family MaskLength: length of the mask for transmitting(2) Mask: the mask to transmit Inventory_16_slots_Nb_UID_Retrieved: pointer to retrieve the number of tags seen during the inventory 16 slots 1. Masklength represents the number of significant bits. The user should ensure that other bits are reset for padding. 2. The inventory flag is reset. Output parameter MyTag: pointer on the structure Return parameter LRIxK_ERROR_CODE: The command failed. Either there is no tag or the tag did not manage to perform the request. LRIxK_ERROR_REQUEST_FLAGS_CODE: The inventory flag is not set. LRIxK_COMMAND_SUCCESS_CODE: The tag answered the command. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |