Back Button AN2555 Datasheet HTML 23Page - STMicroelectronics AN2555 Datasheet HTML 24Page - STMicroelectronics AN2555 Datasheet HTML 25Page - STMicroelectronics AN2555 Datasheet HTML 26Page - STMicroelectronics AN2555 Datasheet HTML 27Page - STMicroelectronics AN2555 Datasheet HTML 28Page - STMicroelectronics AN2555 Datasheet HTML 29Page - STMicroelectronics AN2555 Datasheet HTML 30Page - STMicroelectronics AN2555 Datasheet HTML 31Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 33 page
background image
AN2555 - Application note
New registers
27/33
4.3.2
Software impact
None. On the ST10F269Zx, the 00’E800h to 00’EBFFh address range was mapped onto external
memory but it was recommended to reserve this space for upward compatibility.
4.4
XMISC register
ST10F276Z5: XMISC (EB46h)
XREG
Reset Value: 0000h
4.4.1
Hardware impact
None.
4.4.2
Software impact
None.
On the ST10F269Zx, the CAN clock is the CPU clock but it is divided by 2 when calculating the time
quantum.
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-
-
-
-
-
-
VREGOFF CANCK2 CANPAR ADCMUX
--
--
--
---
--
-
RW
RW
RW
RW
Bit
number
Bit name
Function
0
ADCMUX
Port1L ADC Channels Enable
‘0’: Analog inputs on port P5.y can be converted (default configuration)
‘1’: Analog inputs on port P1.z can be converted. Only 8 channels can be
managed
1CANPAR
CAN Parallel Mode Selection
‘0’: CAN2 is mapped on P4.4/P4.7, while CAN1 is mapped on P4.5/P4.6
‘1’: CAN1 and CAN2 are mapped in parallel on P4.5/P4.6. This is effective
only if both CAN1 and CAN2 are enabled by setting the CAN1EN and
CAN2EN bits in the XPERCON register. If CAN1 is disabled, CAN2 remains
on P4.4/P4.7 even if the CANPAR bit is set.
2
CANCK2
CAN Clock divider by 2 disable
‘0’: Clock provided to CAN modules is CPU clock divided by 2 (mandatory
when fCPU is higher than 40 MHz)
‘1’: Clock provided to CAN modules is directly CPU clock
3VREGOFF
Main Voltage Regulator disable in Power-Down mode
‘0’: Default value after reset and when Power Down is not used
‘1’: Main Regulator is turned off when Power-Down mode is entered
4...15
Reserved



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com