| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
UE48-2OS2D2 bảng dữ liệu(PDF) 83 Page - SICK AG |
|
|
|||||||||||||||||||||||||||||
UE48-2OS2D2 bảng dữ liệu(HTML) 83 Page - SICK AG |
|
83 / 92 page ![]() A B C D E F H I J K L M N O P Q R S T S e n S : c o n t r o l - S a f e c o n t r o l S o l u t I o n S | S I c K 8015528/2012-12-17 Subject to change without notice Safety relays Contact expansions 8 3 ue10-4Xt detailed technical data General data Safety-related parameters Safety integrity level SIL3 (IEC 61508) 1) SILCL3 (EN 62061) 1) Category Category 4 (EN ISO 13849) 1) Performance level PL d (EN ISO 13849) 1) B 10d parameter 1 x 106 switching cycles (AC-15, 230 V, I = 0,5 A) 3.5 x 105 switching cycles (DC-13, 24 V, I = 2 A) 1.2 x 106 switching cycles (DC-13, 24 V, I = 0,5 A) PFHd (mean probability of a dangerous failure per hour) 2.0 x 10-7 (EN ISO 13849) T M (mission time) 4 years (EN ISO 13849) 1) If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit. Electrical data General electrical data Voltage supply A1, A2 Output circuit > 25 V AC / 60 V DC PELV Output circuit ≤ 25 V AC / 60 V DC PELV or SELV Supply voltage A1, A2 24 V AC/DC (20.4 V AC/DC ... 26.4 V AC/DC) Power consumption 2.7 VA (AC), 1.5 W (DC) residual ripple ≤ 2.4 V pp 1) 1) In DC operation, within the limits of Vs. Electrical output circuits: 13/14, 23/24, 33/34, 43/44, 51/52, 61/62, Y1/Y2 response time ≤ 70 ms 1) number of enable current (n/o) contacts 4, relevant for safety number of signalling current (n/c) contacts 2, not safety-relevant number of contactor monitoring (n/c) contacts 1, external device monitoring contact type Positively driven contact material Silver alloy, gold flashed Switching voltage Enable current contact 10 V AC ... 230 V AC / 10 V DC ... 300 V DC Signalling current contact 10 V AC ... 230 V AC / 10 V DC ... 300 V DC Contactor monitoring contact 10 V DC ... 24 V DC Switching current Enable current contact 10 mA ... 6 A Signalling current contact 10 mA ... 2 A Contactor monitoring contact 10 mA ... 100 mA Total current ≤ 12 A usage category AC-15/DC-13 rated operating current (voltage) 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h maximum switching frequency 3600/h mechanical life (relay contacts) 1 x 107 switching cycles electrical life (relay contacts) 2 x 106 switching cycles 1) K1/K2. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |