| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAX17843ACBV bảng dữ liệu(PDF) 96 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX17843ACBV bảng dữ liệu(HTML) 96 Page - Maxim Integrated Products |
|
96 / 131 page ![]() UART Optical Isolation The daisy-chain may use optical isolation instead of trans- former or capacitor isolation (see Figure 68). Device Initialization Sequence Immediately after reset, all device addresses are set to 0x00 and the UART baud rate and receive modes have not been autodetected; therefore, the following initialization sequence is recommended after every reset or after any change to the hardware configuration for differential mode: After the daisy-chain is initialized, each device should be configured for operation as follows: 1) Perform a READALL of the status registers: The ALRTRST bit should be set in all devices to signify a reset occurred. Check for other unexpected alerts. 2) Clear the ALRTRST bit on each device so that future unintended resets can be detected. 3) Change configuration registers as necessary with WRITEALL commands: Configure the alert enables and alert thresholds required by the application. Configure the acquisition mode. 4) Perform all necessary key-on diagnostics. 5) Start the acquisition cycle. 6) Continuously monitor diagnostic and alert status bits. 7) Periodically perform additional diagnostics, as required by the application. Error Checking Data integrity is provided by Manchester encoding, par- ity, character framing, and packet-error checking (PEC). The combination of these features verify stage-to-stage communication both in the write and read directions, with a hamming distance (HD) value of 6 for commands with a length up to 247 bits (counted prior to Manchester- encoding and character framing. This is equivalent to the longest possible command packet for a daisy-chain of up to 13 devices. The data-check byte is present in the READALL and READDEVICE commands to verify that the entire command propagated without errors. Using the data-check and PEC bytes, complete transaction integrity for READALL and READDEVICE command packets can be verified. PEC Errors If the device receiver receives an invalid PEC byte, the ALRTPEC bit is set in the STATUS register. A device does not execute any write command unless the received PEC matches the calculated PEC so to verify the write com- mand execution, the host should perform a READALL to verify the contents of the written register. For returned read packets, the host should store the received data, perform the PEC calculation, and compare the results to the received PEC byte before considering the data to be valid. To support PEC, the host must implement an 8-bit cyclic redundancy check (CRC-8) encoding and decoding algorithm based on the following polynomial: P(x) = x8 + x6 + x3 + x2 + 1 Figure 68. UART Optical Isolation RXLP CFILTER 15pF RFILTER 1.5kΩ VAA FROM UART DATA SOURCE ACPL-M72T 3.3V TO UART DATA SOURCE ACPL-M72T ROPTO RXLN GNDL TXLN MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 96 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |