| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
RT3607CE bảng dữ liệu(PDF) 33 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT3607CE bảng dữ liệu(HTML) 33 Page - Richtek Technology Corporation |
|
33 / 69 page ![]() 33 RT3607CE DS3607CE-01 June 2016 www.richtek.com © Copyright 2016 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. Per Phase Current Sense In the RT3607CE, the current signal is used for load-line setting and over-current protection (OCP). The inductor current sense method adopts the lossless current sensing for allowing high efficiency as illustrated in Figure 11. When inductance and DCR time constant is equal to RXCX filter network time constant, a voltage ILx x DCR will drop on CX to generate inductor current signal. According to Figure 11, the ISENxN is as follows : LX CSx I DCR ISENxN R Where LX / DCR = RXCX is held. The method can get high efficiency performance, but DCR value will be drifted by temperature, a NTC resistor should add in the resistor network on the IMON pin to achieve DCR thermal compensation. In RT3607CE design, the resistance of RCSx is restricted to 680 Ω; moreover, the error of RCSx is recommended to be 1% or smaller. Figure 11. Lossless Current Sense Method ISENxP ISENxN LX DCR RX CX VCORE + - RCSx ILx ISENxN Total Current Sense Total current sense method is a patented topology, unlike conventional current sense method need a NTC resistor in per phase current loop for thermal compensation. The RT3607CE adopts the total current sense method requiring only one NTC resistor for thermal compensation, and NTC resistor cost can be saved by using this method. Figure 12 shows the total current sense method which connects the resistor network between the IMON and VREF pins to set a part of current loop gain for load-line (droop) setting and set accurate over-current protection. IMON REF EQ L1 L2 L3 L4 CS DCR V V = R (I +I +I +I ) R REQ includes a NTC resistor to compensate DCR thermal drifting for high accuracy load-line (droop). Figure 12. Total Current Sense Method VCORE ISEN1P ISEN1N L DCR R C + - RCS IL1 ISEN1N ISEN2P ISEN2N L DCR R C + - RCS IL2 ISEN2N ISEN3P ISEN3N L DCR R C + - RCS IL3 ISEN3N ISEN4P ISEN4N L DCR R C + - RCS IL4 ISEN4N VREF IMON RNTC REQ Load-Line (Droop) Setting The G-NAVPTM topology can set load-line (droop) via the current loop and the voltage loop, the load-line is a slope between load current ICC and output voltage VCORE as shown in Figure 13. Figure 14 shows the voltage control and current loop. By using both loops, the load-line (droop) can be set easily. The load-line set equation is : EQ CS I LL V 1 DCR R 3R A RmΩ R2 A R1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |