| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ST95HF bảng dữ liệu(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST95HF bảng dữ liệu(HTML) 32 Page - STMicroelectronics |
|
32 / 93 page ![]() Commands ST95HF 32/93 DocID025630 Rev 4 For more detailed examples of use with NFC Forum and ISO/IEC 15693 tags, refer to Appendix D on page 69. If Parity Framing mode is used, the parity bit stays unchanged. On transmission, it is not encoded and on reception it is not decoded. The length of Data must be even. Each data byte is accompanied by an additional byte which encodes the parity: <DataByte>, <Parity>, <DataByte>, <Parity> … On reception, bits [6:0] of the parity byte are zeroes; on transmission, bits [6:0] are ignored. 5.7 Listen command (0x05) description In Card Emulation mode, this command waits for a command from an external reader. Before sending this command, the application must select a protocol. After reception of the LISTEN command and the return of a ‘No error’ confirmation, the ST95HF enters Listening mode. The host controller has to use SPI Poll mode or IRQ_OUT pin to detect when a receive frame is available in the ST95HF buffer. The ST95HF will exit Listening mode as soon it receives the ECHO command (0x55) from the Host Controller (MCU) or a command from an external reader (not including commands supported by the ACFILTER command listed in Table 42). In all cases, the ST95HF will send data or an error code to the Host controller (MCU). Table 19. Structure of Parity byte Bit Description 7 Parity bit [6:0] Reserved for future use Table 20. LISTEN command description Direction Data Comments Example Host to ST95HF 05 Command code 0x0500 : Enters a Listening mode where the ST95HF waits for a command from an external reader. 00 Length of data ST95HF to Host 00 Result code 0x0000 : No error. Confirmation that ST95HF now is in Listening mode. 00 Length of data ST95HF to Host 82 Error code 0x8200 : Invalid command length 00 Length of data ST95HF to Host 83 Error code 0x8300 : Invalid protocol or protocol is not supported. For example, application selects protocol ISO/IEC 15693 using command select protocol and then executes the LISTEN command. ISO/IEC 15693 is not supported in Card Emulation mode. 00 Length of data ST95HF to Host 8F Error code 0x8F00 : No field. Command cannot be executed because there is no external field. 00 Length of data |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |