| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PC87310 bảng dữ liệu(PDF) 22 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87310 bảng dữ liệu(HTML) 22 Page - National Semiconductor (TI) |
|
22 / 52 page ![]() 40 Functional Description (Continued) The controller takes best advantage of the internal data separator by implementing a sophisticated ID search algo- rithm This algorithm shown in Figure 4 enhances the PLL’s lock characteristics by forcing the PLL to relock to the crystal any time the data separator attempts to lock to a non-preamble pattern This algorithm ensures that the PLL is not thrown way out of lock by write splices or bad data fields TABLE 4-8 Typical Filter Values for the Various Data Rates (Assuming g6% Capture Range) Data Rate C2 R2 C1 R1 (MFM bs) Filter Values when Using All 3 Data Rates 10M C2C e 0012 mF 560X 510 pF 56 kX 500k C2B e 0015 mF 250300k C2A e 0033 mF Filter Values when Using 250300 and 500 kbs 500k C2B e 0027 mF 560X 1000 pF 56 kX 250300k C2A e 0047 mF 560X Filter Using Only One Data Rate 10M C2 e 0012 mF 560X 510 pF 56 kX 500k C2 e 0027 mF 560X 1000 pF 56 kX 300250k C2 e 0047 mF 560X 2000 pF 56 kX (These values are preliminary and thus are subject to change) TABLE 4-9 Data Rates (MFM) versus VCO Divide-By Factor Data Rate N 1 Mbs 4 500 kbs 8 300 kbs 16 250 kbs 16 PLL DIAGNOSTIC MODES In addition the FDC has two diagnostic modes to enable filter optimization 1) enabling the Charge Pump output sig- nal onto the PUMPPREN pin and 2) providing external control of the Read Gate signal to the data separator Both modes are enabled in the last byte of the Mode Command The Pump output signal indicates when the charge pump is making a phase correction and hence whether the loop is locked or not The Read Gate function when enabled allows the designer to manually force the data separator to lock to the incoming data or back to the reference clock This enables easy veri- fication of the lock characteristics of the PLL by monitoring the FILTER pin and the Pump signal PLL FILTER DESIGN This section provides information to enable design of the data separator’s external filter and charge pump set resis- tor This discussion is for a single data rate filter and can be easily extrapolated to the other filters of Figure 3 Table 4-8 shows some typical filter component values but if a custom filter is desired the following parameters must be consid- ered R1 Charge pump current setting resistor The current set by this resistor is multiplied by the charge pump gain KP which is E25 Thus the charge pump cur- rent is IPUMP e (25) 12VR1 R1 should be set to between 3–12 kX This resistor determines the gain of the phase detector which is KD e IPUMP 2q TLC10591 – 12 FIGURE 4 Read Algorithm-State Diagram for Data 22 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |