| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AS8506 bảng dữ liệu(PDF) 33 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8506 bảng dữ liệu(HTML) 33 Page - ams AG |
|
33 / 89 page ![]() ams Datasheet, Confidential:2013-Sep [1-00] AS8506 – 33 Detaile d Desc rip t ion Trigger Event The AS8506 device enters into NORMAL mode only when a valid command is present on the TRIG_IN pin. There are two commands in the device. • Diagnosis command • Cell balance command When a high pulse of width Tdiag_cmd as shown in Figure 27, is given on TRIG_IN pin, the device performs the following operations. • Compares all connected cell voltages with the set lower operating voltage threshold, and if any of the cell voltage is less than lower threshold, then sets a corresponding flag in the cel_low_thsld_stat_reg register. This is indicated by high pulse on CVT_NOK_OUT pin. • Compares all connected cell voltages with the set higher operating voltage threshold, and if any of the cell voltage is more than higher threshold, then sets a corresponding flag in the cel_high_thsld_stat_reg register. This is indicated by high pulse on CVT_NOK_OUT pin. • Sets a corresponding flag in the temp_stat_reg register if ambient temperature or internal chip temperature is higher than respective thresholds. This is indicated by high pulse on CVT_NOK_OUT pin. • It will enable SAR ADC and starts measuring each cell voltage, and then measures temperature channel measurement. The 12 bits digital value will be stored in corresponding registers. Thus, on diagnosis command the device gives the cell operating voltage, ambient temperature and internal temperature status with respect to its safe operating range. When the TRIG_IN pin is ‘High’ for longer than the status command, the device enters into Balance phase. Depending upon cell voltage status, the device starts balancing the cell voltages. The cell voltage balancing is continued till the high voltage on the TRIG_IN pin. As soon as TRIG_IN goes ‘Low’, the device stops balancing and enters into WAIT mode. Thus, the microcontroller has full control over the balancing time and stop balancing whenever required. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |